DSC-P51/P51M
5-21
10. Auto White Balance 3200K Check 1
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data
Video terminal of
of Page: 1
VIDEO OUT jack
(Note 2)
(75
Ω
terminated)
Specified Value
R ratio: 3F60 to 40A0
B ratio: 3F60 to 40A0
R-Y level data: 007E to 0082
B-Y level data: 007E to 0082
Note 1:
Perform this check after performing after performimng
“Auto White Balance 3200K Standard Data Input”.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
“Auto white Balance 3200K
Standard Data Input” is
completed.
2
6
37
0D
3
6
01
11
Press PAUSE button.
4
6
38
Check the data changes to
“01”.
5
6
01
C1
Press PAUSE button.
6
6
02
Check the data changes to
“01”.
7
0
03
04
8
1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
9
0
03
05
10
1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
11
0
03
2C
12
1
Check that the R-Y level data
(Note 2) satisfied the
specified value.
13
0
03
2D
14
1
Check that the B-Y level data
(Note 2) satisfied the
specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
B6
00
3
Perform “Auto white Balance
3200K Check 2”.