5-23
Address
14
15
16
17
18
19
Data
1C
94
26
EC
13
B9
Address
1A
1B
1C
1D
1E
1F
Data
00
00
00
00
46
00
Address
20
21
22
23
24
25
Data
20
20
23
44
0A
00
2. Flange Back Adjustment
(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Mode
STILL
Subject
Siemens star chart with ND filter for
the minipattern box (Note1)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
14 to 25
Note 1:
Dark Siemens star chart.
Note 2:
Check that the data of page: 6, address: 02 is “00”. If not, turn the
power of the unit OFF/ON.
Preparations before adjustments:
The minipattern box is installed as shown in the following figure.
Note:
The attachment lenses are not used.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage
written on the sheet which is supplied with
the minipattern box.
Adjusting method:
1)
Install the minipattern box so that the distance between it and
the front of the lens of the camera is less than 3cm.
2)
Make the height of the minipattern box and the camcorder equal.
3)
Check that the output voltage of the regulated power supply is
the specified voltage ± 0.01Vdc.
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: 5, address: F1, and set data: FF.
6)
Check that the center of the Siemens star chart and center of
the exposure screen coincide.
7)
Check that the data of page: F, address: 14 to 25 is the initial
value (See table below).
8)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
9)
Select page: 6, address: 01, set data: 27, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses: 14 to 25.)
10) Select page: 6, address: 02, and check that the data is changed
to “01”.
Processing after Completing Adjustments:
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: 0, address: 01, and set data: 00.
4)
Perform “Flange Back Check”.
Fig.5-1-13.
Minipattern box
Below 3 cm
Camera
Table
Red (+)
Regulated power supply
Output voltage: Specified voltage
±
0.01Vdc
Output current: more than 3.5A
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Содержание Cyber-shot DSC-F505
Страница 7: ...1 1 DSC F505 SECTION 1 GENERAL This section is extracted from instruction manual ...
Страница 8: ...1 2 ...
Страница 9: ...1 3 ...
Страница 10: ...1 4 ...
Страница 11: ...1 5 ...
Страница 12: ...1 6 ...
Страница 13: ...1 7 ...
Страница 14: ...1 8 ...
Страница 15: ...1 9 ...
Страница 16: ...1 10 ...
Страница 17: ...1 11 ...
Страница 18: ...1 12 ...
Страница 19: ...1 13 ...
Страница 20: ...1 14 ...
Страница 21: ...1 15E ...