CXD5602 User Manual
-
332/1010
-
11..8
START_IN
TERVAL5
RW 0x0
This designates Sequencer 5’s timer operating frequency division
value.
When SEQ_MODE5 is “0” or “1”, this set value is referred.
As for the calculating formula of the operating frequency, the range of
values that can be set, and set values when using the One-shot
Sequencer, refer to START_INTERVAL3.
7..4
Reserved
RO
0x0
Reserved
3..0
START_IN
TERVAL4
RW 0x0
This designates Sequencer 4’s timer operating frequency division
value.
When SEQ_MODE4 is “0” or “1”, this set value is referred.
As for the calculating formula of the operating frequency, the range of
values that can be set, and set values when using the One-shot
Sequencer, refer to START_INTERVAL3.
3.9.12.3.10
{0x503C} START_INTERVAL9_8 Details
Table SCU (Sensor Control Unit)-118
Local Address: 0x503C
Register Type: RW (read/write)
Reset Value: 0x00000000
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Reserved
S
TA
R
T
_
IN
TER
V
A
L
9
Reserved
S
TA
R
T
_
IN
TER
V
A
L
8
Bits
Name
Type
Reset
Value
Description
31..12 Reserved RO
0x00000 Reserved
11..8
START_I
NTERVA
L9
RW 0x0
This designates Sequencer 9’s timer operating frequency division
value.
When SEQ_MODE9 is “0” or “1”, this set value is referred.
As for the calculating formula of the operating frequency, the range
of values that can be set, and set values when using the One-shot
Sequencer, refer to START_INTERVAL3.
7..4
Reserved RO
0x0
Reserved
Содержание CXD5602
Страница 1: ...CXD5602 User Manual 1 1010 CXD5602 User Manual ...
Страница 36: ...CXD5602 User Manual 36 1010 2 3 Block Diagram Figure Block Diagram 1 CXD5602 Block Diagram ...
Страница 144: ...CXD5602 User Manual 144 1010 GNSS_RAMMODE_SEL 0x3F000FFF SRAM GNSS BB 0 5 ON ...
Страница 835: ...CXD5602 User Manual 835 1010 enable disable ...
Страница 1007: ...CXD5602 User Manual 1007 1010 Revision History Date Revision Description 2019 07 05 1 0 0 Initial version ...