CMT-Z100DiR/Z100iR
3
SECTION 1
SERVICING NOTES
NOTES ON HANDLING THE OPTICAL PICK-UP
BLOCK OR BASE UNIT
The laser diode in the optical pick-up block may suffer electro-
static break-down because of the potential difference generated by
the charged electrostatic load, etc. on clothing and the human body.
During repair, pay attention to electrostatic break-down and also
use the procedure in the printed matter which is included in the
repair parts.
The
fl
exible board is easily damaged and should be handled with
care.
UNLEADED SOLDER
Boards requiring use of unleaded solder are printed with the lead-
free mark (LF) indicating the solder contains no lead.
(
Caution:
Some printed circuit boards may not come printed with
the lead free mark due to their particular size)
: LEAD FREE MARK
Unleaded solder has the following characteristics.
• Unleaded solder melts at a temperature about 40 °C higher
than ordinary solder.
Ordinary soldering irons can be used but the iron tip has to be
applied to the solder joint for a slightly longer time.
Soldering irons using a temperature regulator should be set to
about 350 °C.
Caution:
The printed pattern (copper foil) may peel away if
the heated tip is applied for too long, so be careful!
• Strong
viscosity
Unleaded solder is more viscous (sticky, less prone to
fl
ow)
than ordinary solder so use caution not to let solder bridges
occur such as on IC pins, etc.
• Usable with ordinary solder
It is best to use only unleaded solder but unleaded solder may
also be added to ordinary solder.
NOTE OF REPLACING THE IC102 ON THE DMB19C-
32NUA BOARD
IC102 on the DMB19C-32NUA board cannot exchange with
single. When this part is damaged, exchange the entire mounted
board.
NOTE OF REPLACING THE MS-214 BOARD
When the MS-214 board is damaged, exchange the entire MD
(AU) ASSY.
NOTE OF REPLACING THE TOUCH PANEL BOARD
When the TOUCH PANEL board is damaged, exchange the entire
PANEL (DISPLAY TOP) ASSY.
MODEL IDENTIFICATION
Model
Power Voltage Indication
CMT-Z100DiR/CMT-
Z100iR: AEP model
AC: 220-240V
-
50/60Hz 30W
CMT-Z100iR:
E2 model
AC: 110-120/220-240V
-
50/60Hz 30W
NOTES ON LASER DIODE EMISSION CHECK
The laser beam on this model is concentrated so as to be focused
on the disc re
fl
ective surface by the objective lens in the optical
pickup block. Therefore, when checking the laser diode emission,
observe from more than 30 cm away from the objective lens.
– Back Panel –
Power
Voltage
Indication
RELEASING THE DISC SLOT LOCK
The disc slot lock function for the antitheft of an demonstration
disc in the store is equipped.
Releasing Procedure:
1. Press
[
?/1
] button to turn the power on.
2. Touch the [FU] sensor to select CD function.
3. While
touching
the
[
x
] sensor, press the [
Z
] button for more 5
seconds.
4. The message “UNLOCKED” is displayed and the disc slot is
unlocked.
Note:
When
“
LOCKED
”
is displayed, the slot lock is not released by
turning power on/off with the
[
?/1
]
button.
• Abbreviation
E2
: Colombian, Venezuelan and Puerto Rican models
IP BOARD DISCRIMINATION
In this set, the IP board has been changed in the midway of pro-
duction.
Repair after distinguishing each type set to doing the repair refer-
ring to the following.
– IP Board (Component Side) –
SUFFIX-12: 1-879-950-12
SUFFIX-21: 1-879-950-21