Connection
22
Functions assignable to P.Input1 to P.Input5 (input terminals)
Indication
Function
PLAY/PAUSE The same function as
HX
button on the
main unit
PLAY
The same function as
H
button on the
remote
PAUSE
The same function as
X
button on the
remote
STOP
The same function as
x
button
AMS +
The same function as
>
button on the
remote
AMS –
The same function as
.
button on the
remote
FF
The same function as
M
button
REW
The same function as
m
button
MARK
The same function as MARK button on the
remote
LOCATE
The same function as LOCATE button
EJECT
The same function as
A
EJECT button on
the main unit
Fader PLAY
Performs Fader Play (page 22)
1 Track PLAY
to 20 Track
PLAY
The same function as numeric buttons on
the remote
OFF
No operation
Functions assignable to P.Output1 to P.Output3 (output
terminals)
Indication
Function
PLAY
Grounding during playback on the player
PAUSE
Grounding during pause on the player
NO DISC
Grounding during no disc in the disc
compartment
OFF
Always floating
Do the procedure below to change the function of each
terminal.
1
Press the MENU/EXIT button while the player is
stopped.
“MENU Mode” appears in the display.
2
Rotate the AMS control until “Parallel” appears in
the display, and then push the control.
If “Parallel” is already set to “User,” skip this step
and step 3, and go to step 4.
3
Rotate the AMS control until “User” appears in the
display, and then push the control.
4
Rotate the AMS control until the terminal that you
want to assign function to (e.g., “P.Input1” or
“P.Output2”) appears in the display, and then push
the control.
5
Rotate the AMS control until the function that you
want to assign to the terminal that you selected
appears in the display, and then push the control.
To assign functions to more terminals, repeat steps
4 and 5.
6
Press the MENU/EXIT button to complete the
setting.
Notes
• When “Preset” is selected for “Parallel,” you cannot
select terminals or assign functions to them. To
enable the assigning of functions to terminals, first
select “User” for “Parallel.”
• Doing the procedure above with “Preset” selected for
“Parallel” allows you to check the factory setting for
each terminal.
Electrical specifications for the
PARALLEL connector
Input terminals
Input system
Make contact
Input ON voltage Less than 0.5 V
Input OFF voltage More than 3 V
Opening terminal voltage
5 V
Input pulse width More than 100 msec
Input standing voltage
–0.5 to +10 V
Output terminals
Output system
Open collector for NPN transistor
Remaining voltage at ON
Less than 0.5 V
Maximum current at ON
100 mA
Standing voltage
20 V