– 12 –
Partially lit 1
Partially lit 2
Partially lit 3
Partially lit 4
FLUORESCENT INDICATOR TUBE AND LED
CHECK MODE
This mode is set by pressing the
I
/
u
button while pressing the
[CHECK]
and
[PLUS ONE]
buttons in order in the power-off
(standby) state.
The whole fluorescent indicator tube lights up, and the
[STANDBY]
,
[MEGA CONTROL]
,
[GROUP1-5]
,
[PLUS ONE]
,
·
and
P
LEDs light up.
This mode can be exited by pressing the
I
/
u
button.
SHIPMENT MODE
(Set to this mode when returning the unit to the
user.)
This mode is set by pressing the
I
/
u
button while pressing the
[PUSH ENTER]
and
[PLUS ONE]
buttons in order in the power-
off (standby) state.
The power goes off automatically after the SRAM is all-erased
and the BD is opened (loading out state).
Test points and connecting points:
[MAIN BOARD] – CONDUCTOR SIDE –
AGING MODE
• Mode which repeatedly changes and plays back discs automati-
cally in the unit.
• It will repeat aging as long as no errors occur.
• If an error occurs during aging, it will stop all servos, motors,
etc. instantaneously, display the error number, and stop opera-
tions. However, the stopping conditions differ according to
whether the unit is equipped with the “self-protection function
during errors” described later.
The function serves to maintain the state of the unit when errors
occur.
Sequence of Aging Mode
$
$
$
$
$
$
$
$
$
Order of Disc Change
(1 cycle takes 3 minutes)
$
$
$
1. No. 51
2. No. 20
3. No. 40
4. No. 30
5. No. 10
6. No. 40*
$
$
$
$
1. Disc change
2. Load in
3. TOC read
4. Access of last track
5. 3 second playback
6. Access of first track
7. 3 second playback
8. Load out
*
DISC No. 40 chucks twice during one cycle.
To differentiate, the “
[2nd]
” on the block indicator of the
fluo rescent indicator tube will light up during the second
chucking.
Special Functions in Aging Mode
There are some useful function in the aging mode.
• Disc setting mode*1
• Switching of use/disuse of protection function in errors *2
• Aging cycle count function *3
*1 Disc setting mode:
5 discs are set before setting the aging mode. This mode makes
the setting of these discs more easy.
*2 Switching of use/disuse of protection function in errors:
Function which voluntarily corrects errors which occur dur-
ing normal operations by retries.
If this function is not provided, all operations will be stopped
without retiring. It is suitable for checking errors with low re-
producibility.
If this function is provided, and errors can be corrected by
retries, aging will be continued without stopping.
(The normal aging should be performed with “be”.)
1 DISCS
CD1
A B C D E F
G
1 DISCS
CD1
1 DISCS
2nd
CD1
**
1 DISCS
CD1
**
GROUP FILE
1
TP
(GND)
TP
(AFADJ)
IC201
CN704
CN702
IC501
R504
R505
TP (ADJ)
Содержание CDP-CX57 - 50 Disc Cd Changer
Страница 34: ... 44 Page 31 Page 36 ...