SERVO SYSTEM ADJUSTMENTS
1. CAP FG Offset Adjustment (VC-195 board)
Improve the capstan servo characteristic. If it is not correct. jitters
will increase.
Mode
Camera recording (SP mode)
Subject
Arbitrary
Measurement Point
Pin
!™
of CN910 (CAP FG)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
69
Specified value
Duty = 50
±
1%
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 01, and set data: 81, and press the PAUSE
button of the adjustment remote commander. (to start up
automatic CAP FG offset adjustment.)
3) Select page: 2, address: 02, and check that the data is “01”.
4) Check that Duty of CAP FG signal satisfies the specified value.
If not, select page: 2, address: 01, set data: 00, and press the
PAUSE button, and then, repeat steps 2) to 4).
5) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjustment remote commander.
6) Select page: 0, address: 01, and set data: 00.
2. Switching Position Adjustment (VC-195 Board)
If deviated in this case causes switching noise or jitter on the played
back screen.
Mode
Playback
Signal
Alignment tape:
For tracking adjustment
(WR5-1NP (NTSC))
(WR5-1CP (PAL))
Measurement Point
CH1: Pin
!¡
of CN910 (RF SWP)
CH2: Pin
6
of CN910 (PB RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
7C, 7D
Specified Value
t1 = 0
±
10
µ
sec
Note 1:
NTSC model :
CCD-TRV75/TRV75PK/TRV715
PAL model :
CCD-TRV3E/TRV13E/TRV23E/
TRV45E/TRV55E/TRV65E/TRV69E
Adjusting Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 2A, and set data: 20, and press the PAUSE
button of the adjustment remote commander.
3) Select page: F, address: 7C, change the data and minimize “t1”,
and then press the PAUSE button of the adjustment remote
commander. (Coarse adjustment)
4) Select page: F, address: 7D, change the data and adjust so that
the switching position (t1) becomes the specified value. (Fine
adjustment)
5) Press the PAUSE button of the adjustment remote commander.
6) Select page: F, address: 2A, and set data: 00, and press the PAUSE
button of the adjustment remote commander.
7) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-5.
Fig. 5-3-6.
Содержание CCD-TRV65E, CCD-TRV3E, CCD-TRV15E, CCD-TRV23E, CCD-TRV35E
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......