51
Additional Information
Self-diagnosis display
Five-digit display
Cause and/or Corrective Actions
• You are using a battery pack that is not an
“InfoLITHIUM” battery pack.
c
Use an “InfoLITHIUM” battery pack. (p. 12)
• Moisture condensation has occurred.
c
Remove the cassette and leave your camcorder for at
least 1 hour to acclimatize. (p. 54)
• The video heads are dirty.
c
Clean the heads using the Sony V8-25CLD cleaning
cassette (not supplied). (p. 55)
• A malfunction other than the above that you can service
has occurred.
c
Remove the cassette and insert it again, then operate
your camcorder.
c
Disconnect the power cord of the AC power adaptor or
remove the battery pack. After reconnecting the power
source, operate your camcorder.
• A malfunction that you cannot service has occurred.
c
Contact your Sony dealer or local authorized Sony
service facility and inform them of the 5-digit code.
(example: E:61:10)
If you are unable to rectify the problem even if you try corrective actions a few times,
contact your Sony dealer or local authorized Sony service facility.
Your camcorder has a self-diagnosis display
function.
This function displays the current condition of
your camcorder as a 5-digit code (a combination of
a letter and figures) in the viewfinder or the
display window. If a 5-digit code is displayed,
check the following code chart. The last two digits
(indicated by
ss
) will differ depending on the
state of your camcorder.
C:21:
ss
Viewfinder
Self-diagnosis display
•C:
ss
:
ss
You can service your camcorder
yourself.
•E:
ss
:
ss
Contact your Sony dealer or local
authorized Sony facility.
E:61:
ss
E:62:
ss
C:31:
ss
C:32:
ss
C:04:
ss
C:22:
ss
C:21:00