1-2-8. V SUB Adjustment (VC-173 board)
When adjustments are off, and the target object is shown under high brightness, the image may become blurred or fuzzy.
Subject
Not required
Measurement point
Not required
Measuring instrument
Not required
Adjustment page
F
Adjustment address 04
Adjusting method :
Page
Address
Data
Procedure
Conditions
1
6
0 1
Release the protect.
2
F
04
Change data with the PLAY and STOP buttons, and input
the data from table
of Fig. 6-l
3
F
04
Press the PAUSE button.
4
6
00 00
Close.
(Example)
When the display shows an
the Vsub data equals 7D.