![Sony CA-950 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/sony/ca-950/ca-950_installation-and-maintenance-manual_416286006.webp)
1-2 (E)
CA-950/950P IMM
1-2. Connectors and Cables
1-2-1. Connector Input/Output Signals
.....
PROMTER
*
*
*
*
*
1
/GENLOCK
*
*
*
*
*
2
BNC 75
Z
1.0 V p-p
*
1: In connection with CCU
*
2: Standalone use
.....
TEST OUT
BNC 75
Z
1.0 V p-p
.....
SERIAL IN/SERIAL OUT
BNC
Based on SMPTE259M
REMOTE (8P FEMALE)
(External view)
No. Signal
Specifications
1
TX (
+
)
BVP SERIAL DATA
2
TX (
_
)
3
RX (
+
)
RM SERIAL DATA
*
1
,
4
RX (
_
)
CA-905L IIC DATA
*
2
5
VIDEO (G)
GND for VIDEO
6
POWER (
+
) OUT
10.5 V to 17 V,
500 mA (MAX)
7
POWER (
_
) OUT
GND for
+
12 V
8
VIDEO (X) OUT
VBS 1.0 V p-p, Zo = 75
Z
CHASSIS GND
CHASSIS GND
*
1 : Standalone use
*
2 : In connection with CCU
RET CONT (6P FEMALE)
(External view)
No. Signal
Specifications
1
INCOM 1
Zi
>
10 k
Z
MIC ON/OFF IN
ON: GND
OFF: OPEN
2
INCOM 2
Zi
>
10 k
Z
MIC ON/OFF IN
ON: GND
OFF: OPEN
3
GND
4
RET 3 ON/OFF IN
Zi
>
10 k
Z
ON: GND
OFF: OPEN
5
RET 1 ON/OFF IN
Zi
>
10 k
Z
ON: GND
OFF: OPEN
6
RET 2 ON/OFF IN
Zi
>
10 k
Z
ON: GND
OFF: OPEN
INCOM 1/2 (5P FEMALE)
(External view)
No. Signal
Specifications
1
INCOM MIC
_
20 dBu
IN (Y)
(CARBON MIC)
2
INCOM MIC
_
60 dBu
IN (X)
(DYNAMIC MIC)
3
GND (PGM)
4
INCOM
_
20 dBu
RECEIVE OUT
(with INCOM level control
set to mechanical center)
5
PGM 1/2 OUT
_
20 dBu
(with PGM level control
set to mechanical center)
1-2. Connectors and Cables
Содержание CA-950