1-19 (E)
VPL-VW90ES
1-4. Indicator
The error status of the this units are indicated by the type of
fl
ashing of indicator. The top cover has the
ON/STANDBY indicator and the LAMP/COVER indicator. Various error contents are indicated by the
type of
fl
ashing of indicator. For details of the types of indicator
fl
ashing and the error statuses, refer to
the list shown below.
ON/STANDBY Indicator (Red
fl
ashing)
Error Name
Flash Frequency
Status
Temperature Error
ON
OFF
2 Times
The temperature inside of the unit is too
high.
AC Error
ON
OFF
3 Times
AC voltage is not correct.
Fan Error
ON
OFF
4 Times
Each fan does not work normally.
Lens Protector
Error
ON
OFF
5 Times
The lens protector is not open correctly.
Power Error
ON
OFF
6 Times
The power is not turned on correctly.
System Error 1
ON
OFF
10 Times
The sub CPU can not obtain the data from
the EEPROM when the sub CPU works.
System Error 2
ON
OFF
11 Times
The main CPU can not obtain the data
from the EEPROM when the main CPU
works.
System Error 3
ON
OFF
12 Times
The main CPU does not work normally.
LAMP/COVER Indicator (Red
fl
ashing)
Error Name
Flash Frequency
Status
Cover Error
ON
OFF
2 Times
The lamp cover or
fi
lter holder is opened.
Connector of the temperature sensor
board (TA board and TL board) is discon-
nected.
Lamp Error
ON
OFF
3 Times
The lamp is not lighting.
Содержание BRAVIA VPL-VW90ES
Страница 1: ...VIDEO PROJECTOR VPL VW90ES REMOTE COMMANDER RM PJVW85 RM PJVW85J SERVICE MANUAL 1st Edition ...
Страница 4: ......
Страница 8: ......
Страница 52: ......
Страница 100: ......
Страница 114: ......
Страница 152: ......
Страница 159: ...6 7 VPL VW90ES 6 7 GA GA 2 1 A B C D E F 3 4 G GA B SIDE SUFFIX 11 ...
Страница 161: ...6 9 VPL VW90ES 6 9 GB GB GB B SIDE SUFFIX 11 2 1 A B C D E F 3 4 ...
Страница 162: ......
Страница 167: ......