background image

1-8(E)

BKSI-2050/2050P

4. Location and Function of Switches/LEDs

!\

!\

!\

!\

!\

S602: (Factory use only)

      Factory setting : Fixed to all OFF.

!=

!=

!=

!=

!=

S401-1: Free-running adjustment switch for
the parallel-serial conversion

Selected to the “ON” when free-running adjusting for
the parallel-serial conversion. (When selecting to the
“ON”, the SERIAL OUT is not provided.)
Factory setting : OFF
S401-2: (

Factory use only

)

Factory setting : Fixed to OFF.

![

![

![

![

![

S600: Microcomputer RESET switch

n

Under the normal operation, never press this switch.

!]

!]

!]

!]

!]

S601-1: Auto freeze switch

       Selected the auto freeze function that is automatically

selected into the FREEZE mode if the input signal is
not received.

       Only when selecting into the REF mode {when the

LOCK MODE switch is selected to the “REF”}, the
selection of this switch become possible.
S601-3: Line operation setting switch
Selected the optional line of the vertical blanking into
the Y/C separation mode or B&W mode.

ON

: Y/C separation mode

OFF : B&W mode

S601-5, S601-6, and S601-7:
Line setting switch for SETUP REMOTE
Selected the line that is removed the SETUP within the
vertical blanking period. (BKSI-2050 only.)
S601-7: ON Removed the SETUP of the lines 10 and

later of the odd field.
Removed the SETUP of the lines 273
and later of the even field.

S601-7: OFF Removed the SETUP of the lines with

selected at the switches S601-5 and S601-6.

S601-5

S601-6

Setup Remove Range

ON

ON

Odd field: Lines 22 and later
Even field: Lines 285 and later

ON

OFF

Odd field: Lines 22 and later
Even field: Lines 284 and later

OFF

Odd field: Lines 21 and later
Even field: The latter half of lines 283
and later

S601-2, S601-4, and S601-8: (

Factory use only

)

The factory settings are shown below.
(The    marks indicate the positions of the switch knobs.)

1

2

3

4

5

6

7

8

ON

Содержание BKSI-2050

Страница 1: ...KSI 2050 ANALOG NTSC 4 2 2 CONVERTER BOARD BKSI 2050P ANALOG PAL 4 2 2 CONVERTER BOARD INSTALLATION MANUAL 1st Edition Revised 1 Serial No 10001 and Higher BKSI 2050 Serial No 10001 and Higher BKSI 2050P ...

Страница 2: ... Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de réduire...

Страница 3: ...1 2 Installation of the Board 1 2 2 1 Plug in Board Installation 1 2 2 2 Connector Panel Installation 1 3 3 Connection 1 4 3 1 Location and Function of Connectors 1 4 3 2 Connection Connector 1 5 4 Location and Function of Switches LEDs 1 6 5 Specifications 1 9 6 ISR 1 10 6 1 Overview 1 10 6 2 ISR Use Environment 1 11 6 3 Commands 1 12 ...

Страница 4: ...n the connector panel and the matching connectors and cables 4 location and Function of the Switches LEDs This section describes the location and function of the switches and LEDs on the plug in board and setting at the factory 5 Specifications This section describes the specifications of BKSI 2050 2050P 6 ISR This section describes the overview of the ISR 1 system 1 ISR Interactive Status Reporti...

Страница 5: ...to a component serial digital video signal distributed into four output signals and finally output n This connector is not received the black and white signal signal with jitter and signal with unstable the SCH The parts list of BKSI 2050 2050P is as follows BKSI 2050 ANALOG NTSC 4 2 2 CONVERTER BOARD Plug in board DEC 82 board 1 Connector panel CN 1216 board 1 Installation guide 1 Installation ma...

Страница 6: ... and shield plate Refer to the Installation Manual supplied with SIU 80 2 Set the switches on the board Refer to Section 4 3 Insert the board into a slot and then turn the board levers in the direction of the arrow 1 and connect the board securely to the connector of the SIU 80 s mother board 4 Install the shield plate Then attach the model label supplied with board on the right side of the shield...

Страница 7: ...gently 2 Installatin of the Board 2 2 Connector Panel Installation Flow for installation General information for installation The connector panel is inserted into the same slot as the plug in board installed in the front of SIU 80 The model label supplied with the connector panel is attached to the chassis to prevent the panel inserting into the incorrect slot when the connector panel replacement ...

Страница 8: ... type Provided the FRAME PULSE signal in synchronized with the digital video output signal Used the synchronized signal as the reference signal of optional Audio AD Converter Board BKSI 2070 4 4 4 4 4 DIGITAL OUT digital signal output connectors BNC type Converted the signal with provided to the ANALOG IN connector to the 4 2 2 component serial digital signal The converted signal is synchronized w...

Страница 9: ...nnectors on the connector panel when installing or servicing use the connector with listed below or equivalent BKSI 2050 2050P Matching Connector Cable Panel Indication Connector Connector Cable Sony Part No ANALOG IN BNC 75Ω BNC 75Ω 1 560 069 11 FRAME PULSE OUT BELDEN 8281 cable DIGITAL OUT 1 4 ...

Страница 10: ...erated as the frame synchronizer INPUT Provided the output signal in synchronized with the input signal The delay time between input and output is minimum The delay time is about 91 4 µs about 1 5h for NTSC model and is about 153 3 µs about 2 5h for PAL model Factory setting REF 5 5 5 5 5 S4 S5 and RV2 SYSTEM H PHASE system phase adjustment Selected the delay time of the digital video output signa...

Страница 11: ...RENCE reference signal indicator Displayed the presence or absence of the reference signal when selecting into the REF mode when the LOCK MODE switch S3 is selected to the REF Lights green When the reference timing signal is supplied from the SIU 80 to the DEC 82 82P board Lights red When the reference timing signal stops to be providing Lights off When selecting into the INPUT mode when the LOCK ...

Страница 12: ...e possible S601 3 Line operation setting switch Selected the optional line of the vertical blanking into the Y C separation mode or B W mode ON Y C separation mode OFF B W mode S601 5 S601 6 and S601 7 Line setting switch for SETUP REMOTE Selected the line that is removed the SETUP within the vertical blanking period BKSI 2050 only S601 7 ON Removed the SETUP of the lines 10 and later of the odd f...

Страница 13: ... output Analog input ANALOG IN connector BNC type 1 1 0 V p p 75 Ω BKSI 2050 NTSC analog composite video signal with loop through output BKSI 2050P PAL analog composite video signal with loop through output Digital output DIGITAL OUT connector BNC type 4 0 8 V p p 75 Ω 4 2 2 component serial digital video signal Video characteristics Sampling frequency Input 14 318 MHz NTSC 17 734 MHz PAL Output Y...

Страница 14: ...ion is contained in an analog input signal or the burst portion is not judged to be contained PROCESS ERROR Indicates that the communication between the main CPU and each IC is possible on the board n It is possible to sellect from among three levels ERROR WARNING and DON T CARE for each message by using SETUP command Operation status Message Status Display 1 Description INPUT GAIN UNITY Indicates...

Страница 15: ...e ROM mounted on the board Board name ROM name version board address and raw ROM name 6 2 ISR Use Environment The ISR function is controlled by Sony application program software For the program software use installation and operation of a personal computer in which this program software can be used consult with your local Sony s sale service office The preparation below is required when managing t...

Страница 16: ...pport Support RST O IDN O FLAGS O Only Power Cycled on STATUS O CMDERR O MSG O UPLOAD TYPE O TYPE VSETTBL Response Support Support ATN OPC O ATN CMDERR O ATN QRESP O SONY Private Command Support Support SETUP O error level check SETUP parameter value O error level setting DEVID device id O 6 ISR ...

Страница 17: ...des acquéreurs de l équipement décrit dans ce manuel Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschli...

Страница 18: ...Printed in Japan Sony Corporation 1997 6 16 Broadcast Products Company 1995 Published by Broadcast Products Company BKSI 2050P CE BKSI 2050 UCJ J E 3 189 229 02 ...

Отзывы: