background image

1-4 (E)

BKSI-2020

2. Installation of Board

SIU-80

BVTT 3

X

6

Connector panel

Model label

3.

Attach the model label supplied with the BKSI-2020 in
the chassis near the slot to install the board.

n

After the connector panel is inserted into a slot, the
model label cannot be seen.

4.

Insert the connector panel to the matching slot and fix
the panel by the two screws securing the rear blank
panel.

Connector panel removal

1.

Turn off the power of SIU-80 and unplug the appli-
ance from the outlet.

2.

Remove the two screws securing the connector panel
and remove the connector panel.

m

• When removing the connector panel, move the panel

to the right and left slowly until the connection with
the mother board is sufficiently loose, then remove
the connector panel gently.

• Panels must be held by the plugs of the cables which

are connected to the BNC cables.

SIU-80

Rear blank panel

BVTT 3

X

6

2-2.

Connector Panel Installation

General information for installation

• The connector panel is inserted into the same slot as the

plug-in board installed in the front of SIU-80.

• The model label supplied with the BKSI-2020 is at-

tached in the chassis to prevent the panel inserting into
the incorrect slot when the connector panel replacement
and others.

w

Do not install with turning the power on

Touching the power contact portion or the primary wind-
ing circuit may cause electric shock.
For safety reason, turn off the power and unplug the
appliance from the outlet before starting the installation.

Procedures

1.

Turn off the power of SIU-80 and unplug the appli-
ance from the outlet.

2.

Remove the rear blank panel. (Refer to the Installation
Manual supplied with the SIU-80.)

Содержание BKSI-2020

Страница 1: ...BIT RATE REDUCTION ENCODER BOARD BKSI 2020 INSTALLATION MANUAL 1st Edition Revised 2 Serial No 10001 and Higher ...

Страница 2: ...strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de réduire les risques de décharge électrique d incendie ou de blessure n effectuer que les réparations indiquées dans le...

Страница 3: ...oard 1 3 2 1 Plug in Board Installation 1 3 2 2 Connector Panel Installation 1 4 3 Connection 1 5 3 1 Location and Function of Connectors 1 5 3 2 Connecting Connector and Cable 1 5 3 3 Signal Input Output 1 6 4 Location and Function of Switches LEDs 1 6 4 1 ENC 29 Board 1 6 4 2 IO 114 Board 1 8 4 3 Selection of Audio Input Signal 1 8 5 Specifications 1 9 6 ISR 1 11 6 1 Overview 1 11 6 2 ISR Use En...

Страница 4: ...This section describes the location and function of connectors on the connector panel and the matching connectors and cables 4 Location and Function of Switches LEDs This section describes the location and function of the switches and LEDs on the plug in board and setting at the factory 5 Specifications This section describes the specifications of BKSI 2020 6 ISR This section describes the overvie...

Страница 5: ...ol devices which are equipped with the setting function The following functions can be controlled in addition to the above described functions by the external devices using the SONY DISK PROTOCOL BKSI 2020 can be also controlled using the VS BUS via SIU 80 Selection of the GOP 3 size and the compression rate for the video signal Setting of SDDI DESTINATION ADDRESS meaning a transmission address of...

Страница 6: ...ST SG VITC SDDI ENC BKSI 2010 SDC SCSI HDD LTC SDDI VIDEO BRR ENC SDI DEC SDDI PACK APPLICATION CONTROLLER REC STOP etc VS BUS RS 422A SMS Software IDC BKSI 2040 1 Overview SMS Server Management System Software AD Converter Analog NTSC PAL 4 2 2 Converter IDC Intelligent Device Controller SDC Disk Control Board HDD Hard Disk Drive ...

Страница 7: ...board is inserted Procedures 1 Turn off the power of the SIU 80 and remove the front panel and shield plate Refer to the Installation Manual supplied with SIU 80 2 Insert the board into a slot and then turn the board levers in the direction of the arrow 1 and connect the board securely to the connector of the SIU 80 s mother board 3 Install the shield plate Then attach the model label on the right...

Страница 8: ...remove the connector panel gently Panels must be held by the plugs of the cables which are connected to the BNC cables SIU 80 Rear blank panel BVTT 3X6 2 2 Connector Panel Installation General information for installation The connector panel is inserted into the same slot as the plug in board installed in the front of SIU 80 The model label supplied with the BKSI 2020 is at tached in the chassis t...

Страница 9: ...connector does not accept SONY VTR PROTOCOL signal 6 SDDI OUTPUT connector BNC type 2 pcs Provides the SDDI serial digital data interface signal 3 2 Connecting Connector and Cable If any cable is connected to the connectors on the connector panel when installing or servicing use the connector or cable listed below or equivalent BKSI 2020 Connector Matching Connector Cable Panel Indication Connecto...

Страница 10: ... When an error is detected in the system control it lights in red 2 D3304 A 3 Video Error indicator When an error is detected in the video block it lights in red 3 D3305 A 4 Audio Error indicator When an error is detected in the audio block it lights in red 4 D3307 A 4 Test SG indicator When the test signal generator operates in the board it lights in green 5 D3306 A 4 Input Error indicator When a...

Страница 11: ... OFF 0 S3000 A 8 Test Mode switch S3000 1 to S3000 7 settings are made active after the S3000 8 is set to ON The setting is changed in the following procedure 1 Set S3000 8 to ON 2 Change the S3000 1 to S3000 7 settings n If returns to the factory setting 1 Set S3000 8 to OFF 2 Push the reset switch S3001 In the normal operating use this switch with factory setting as shown below marks indicate th...

Страница 12: ...00 8 is held in the ON position CN1101 A 11 Maintenance connector This connector is used for the monitor program at the maintenance mode A personal computer is connected to this connector For details refer to Maintenance Manual 4 2 IO 114 Board n mark followed by the Ref No shows the address of switch or indicator on the board 1 RV100 C 11 Free run Frequency Adjustment volume For the details of th...

Страница 13: ...er consumption 33 W Input Output Digital input SDI INPUT connector BNC type 1 pc with active through output 75 Ω 4 2 2 component serial digital interface SDI signal input SMPTE 259M 270 MHz ITU 656 AUDIO INPUT connector BNC type 2 pcs 75 Ω Digital audio signal input CH 1 2 and CH 3 4 AES EBU format TC IN connector XLR 3 pin type female 1 pc Time code signal input 0 5 thru 18 0 Vp p 10 kΩ balanced ...

Страница 14: ... sample B Y R Y signal 360 sample Encoding line 525 59 94 512 line 625 60 608 line Bit Rate MAX 50 Mbps Compression Format Operation compensation MC discrete cosine convert DCT Audio characteristics Sampling frequency 48 kHz synchronized to video Quantization 16 bits sample Input channel Non compressed 4 channels Design and specifications are subject to change without notice ...

Страница 15: ...MEP TO ENC INTERFACE The parity error is detected during data transmission from PARITY ERROR BRR MEP to the BRR encoder VIDEO BRR ENC SDRAM R W ERROR The read write error is detected in SDRAM connected to the BRR encoder VIDEO BRR ENC TO MEP INTERFACE The parity error is detected during data transmission from PARITY ERROR the BRR encoder to BRR MEP VIDEO BRR MEP SDRAM R W ERROR The read write erro...

Страница 16: ...elected Other warning Message Description TEST MODE ACTIVE BY DIP SWITCH The test mode is active S3000 8 is set to ON Operation status Message Status Display Description VIDEO INPUT SDI SIGNAL Indicates the setting of the input video signal 100 COLOR BAR TEST SIGNAL 75 COLOR BAR TEST SIGNAL MULTI BURST TEST SIGNAL BLACK TEST SIGNAL AUDIO CH INPUT SDI SIGNAL Indicates the setting of the input audio...

Страница 17: ...OM mounted on the board Board name ROM name version board address and blank ROM name 6 2 ISR Use Environment The ISR function is controlled by Sony application program software For the program software use installation and operation of a personal computer in which this program software can be used consult with your local sony s sales service office The preparation below is required when managing t...

Страница 18: ......

Страница 19: ...des acquéreurs de l équipement décrit dans ce manuel Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind und ausschli...

Страница 20: ...Printed in Japan Sony Corporation 1997 3 16 Broadcast Products Company 1996 Published by Broadcast Products Company BKSI 2020 SY J E 3 190 291 03 ...

Отзывы: