1-18(E)
BKSI-2010
5. ISR
5.
ISR
5-1.
Overview
The BKSI-2010 corresponds to an ISR (Interactive Status Reporting) function.
Using this function, the status of the BKSI-2010 or the contents of a generated error can be intensively
monitored and managed on the monitor screen of a personal computer. The data displayed on the monitor
screen can be stored or printed as a file.
The major functions of the BKSI-2010 are as follows.
Monitor functions
n
• If a message is displayed, check whether the normal signals are input.
• “*” in the message means a numerical character (* = 1,2, or 3 • • •).
• Error message
[SCSI Block error]
Message
Description
SCSI BUS STOP
SCSI bus is stopped.
• Warning message
[Recording Block warning]
Message
Description
REC MAIN MEMORY FULL
A recording block memory is full
SDDI CRC ERROR RX
CRC error is detected in the SDDI input signal
[SCSI Block warning]
Message
Description
ILLEGAL PHYSICAL FORMAT
Physical format of the disk is illegal
SCSI BUS PARITY ERROR
A parity error on SCSI bus is detected
SCSI DATA ERROR
A data error is occurred on the SCSI.
SCSI DEVICE
*
HARDWARE ERROR
A hardware trouble is detected in No.
*
of SCSI device
SCSI DEVICE
*
NOT RESPOND
There is no response from No.
*
of SCSI device
SCSI IOP OVERFLOW
An area for SCSI I/O process is overflowed
SCSI QUEUE FULL
A command queue of SCSI device is overflowed
UNKNOWN SCSI DEVICE
Unsupported SCSI device is connected
[Communications Block warning]
Message
Description
ISR COMMUNICATION ERROR
ISR communication error is detected
REMOTE A COMMUNICATION ERROR
A communication error in REMOTE A port is detected
REMOTE B COMMUNICATION ERROR
A communication error in REMOTE B port is detected
VSBUS COMMUNICATION ERROR
VS-BUS communication error is detected