1-9(E)
BKSI-2010
2. Information of BKSI-2010
8
D1101(A-9):SDDI RX indicator
When receiving the SDDI signal, it lights in green.
9
D1102(A-9):REC indicator
When DMA data for the record process block is
transferred on SCSI, it lights in green.
0
D2201(A-9):SDDI TX1 indicator
!-
D2202(A-9):SDDI TX2 indicator
When encoding the SDDI output data, it lights in
green.
There are two encoder types (TX1 and TX2) of SDDI
output data and the type is selected automatically in
the board.
!=
D2203(A-10):PB indicator
When DMA data for the playback process block is
transferred on SCSI, it lights in green.
![
S3001(A-10) :RESET switch
(Push switch type)
Used for resetting CPU or starting the self-diagnostics.
2-7-2. IO-116 Board
1
RV100(D-12):Free-run Frequency Adjustment
volume
For the details of the adjustment, refer to Maintenance
Manual.
2
RV300(C-10):Free-run Frequency Adjustment
volume
For the details of the adjustment, refer to Maintenance
Manual.
(Component side/A side)
1
RV300
1
RV100