1-2 (E)
BKMA-U70XGI
1-3. Installing TeraTermPro (Version 2.3)
1.
Copy the “Tools/ttermp23” folder and all the folders and files under it that are contained in the CD-
ROM supplied, to TEMP or the desired folder of a personal computer.
2.
Click “setup.exe” in the “ttermp23” folder.
TeraTermPro (version 2.3) is installed in a personal computer.
3.
Copy the “SY253data” folder in the “Tools/TeraTerm/” in the CD-ROM supplied, to the same folder
where the TeraTermPro (version 2.3) is installed.
n
In order to start up TeraTermPro (version 2.3), click “ttermpro.ex” in the “Ttermpro” folder.
1-4. Downloading Parameters from the SY-253 Board
1.
Remove the ornamental panel (A) from the MAV-70.
(Refer to Section 2-2-1 of the Maintenance Manual Volume 1.)
2.
Set the switch S3 on the front panel of the MAV-70 to INT.
3.
Connect the MAV-70 to a personal computer with the RS-232C cross cable.
4.
Turn on the main power of the MAV-70.
5.
Start up TeraTermPro (version 2.3).
6.
The Tera Term New connection display appears. Click “serial” and press the
[OK]
button.
1-3. Installing TeraTermPro (Version 2.3)
1-4. Downloading Parameters from the SY-253 Board
COM1
RS-232C cable (9P-9P)
Personal Computer
Содержание BKMA-U70XGI
Страница 1: ...UPGRADE KIT FOR MAV 70 BKMA U70XGI INSTALLATION MANUAL 1st Edition Serial No 10001 and Higher ...