4-1 (E)
BKMA-U70XGI
Section 4
Uploading Parameters to the SY-253A Board
This section describes the procedure to upload the original parameters that are downloaded from the
previous SY-253 board in Section 1, to the SY-253A board.
4-1. Equipment Required
(The software TeraTermPro and the parameter uploading program are contained in the CD-ROM
supplied.)
.
Personal computer (Windows95/98/2000/NT4.0)
.
RS-232C cross cable
.
TeraTermPro (Version 2.3)
.
PutSyPr10.ttl (SY253 DataUpload Macro)
4-2. Uploading Parameters to the SY-253A Board
1.
Remove the ornamental panel (A) from the MAV-70.
(Refer to Section 2-2-1 of the Maintenance Manual Volume 1.)
2.
Set the switch S3 on the front panel of the MAV-70 to INT.
3.
Connect the MAV-70 to a personal computer with the RS-232C cross cable.
Switch S3
COM1
RS-232C cable (9P-9P)
Personal computer
Содержание BKMA-U70XGI