3-13 (E)
MAV-70
4.
Select “EXT232C” using
and
buttons and “-7-” (SY-253 board) using
and
buttons.
5.
Press the
[ENTER]
button several times and display “SY MAIN”.
6.
Exit the menu.
7.
Turn on the power of personal computer and activate Windows 95.
8.
Activate the terminal software (Hyperterminal).
9.
Set the communication rate.
Communication port
COM1
Baud rate
38,400 bps
Parity
None
Flow control
None
Stop bit length
1
Data bit length
8
10. Open the recording file (e.g., ABC file).
11. Confirm the file handle.
12. Start the recording.
Rdy Rdy Rdy Reg Rdy Rdy Rdy Rdy
-1- -2- -3- -4- -5- -6- -7- -8-
Exit
Param
>EXT232C
Service : Board Slot 7 SY MAIN
Rdy Rdy Rdy Reg Rdy Rdy Rdy Rdy
-1- -2- -3- -4- -5- -6- -7- -8-
Exit
Param
>EXT232C
Service : Board Slot 7 SY MAIN
Command :
DPM
\
TOMCP
\
DISK
\
OPENREC
\
01
\
00
\
00
\
ABC
"
Slot number in which the ENC-47 board is inserted
Command :
DPM
\
DUMP
\
OPENSTATUS
"
Return From MAV-70 :
PORT=01 : 08 01 01 04
PORT=02 : 00 00 00 00
PORT=03 : 00 00 00 00
The third numerical value is
a file handle.
Slot number
Command :
DPM
\
TOMCP
\
DISK
\
REC
\
01
"
File handle