2-2 (E)
BKMA-7030/7060
2-1-2. DA-134 Board (BKMA-7060)
Switches
Ref. No.
Address
Name
Function
Factory Setting
S301
(E-3)
CH-2 head room select
Selects the head room of
20 dB
switch
audio input CH-2
(Selects from 20, 18, 16 dB)
S302
(E-5)
CH-1 head room select
Selects the head room of
20 dB
switch
audio input CH-1
(Selects from 20, 18, 16 dB)
S303
(E-1)
CH-2 level select switch
Selects the standard level of
+
4 dBm
audio input CH-2
(Selects from
+
4, 0,
_
3,
_
20 dBm)
S304
(E-3)
CH-1 level select switch
Selects the standard level of
+
4 dBm
audio input CH-1
(Selects from
+
4, 0,
_
3,
_
20 dBm)
2-1. Description of Internal Switches and Indicator
S303
S304
S302
S301
E
D
F
G
6
7
8
5
4
3
2
1
A side (Component side)