2-1 (E)
MAV-2000
Section 2
Service Overview
RK4
x
16
Filter (B)
Filter (A)
Stopper
Stopper
2-1. Cleaning the Air Filter
A filter is fitted on the rear side of the front panel assembly
of the unit. If accumulated dust on the filter impedes the
flow of air, the inside may heat up and troubles may occur.
Clean the filter periodically.
Cleaning
1.
Turn off the main power of the MAV-2000.
2.
Fully loosen the three screws (with drop-safe).
3.
Open the front panel assembly in the direction of the
arrow.
4.
Press the stopper in the direction of the arrow to lock
the front panel.
5.
Remove the filter (A) and filter (B).
6.
Remove the dust from the filter using a vacuum.
7.
Attach the filter in reverse order of the disassembly
procedure.
8.
Unlcok the stopper and close the front panel.