background image

13

Connections

1

Turn off the MAIN POWER switch of the monitor 
before connecting the units.

2

Set the NETWORK switch of the monitor and the unit 
to PEER TO PEER.

3

Connect the LAN (10/100) connector of the monitor 
and the LAN (10/100) connector of the unit by using 
the SMF-700 or the cable supplied with the controller 
attachment stand such as BKM-37H, or a 10BASE-T/
100BASE-TX straight LAN cable (shielded-type, 
optional).

When an optional LAN cable is connected, use a 
shielded-type cable to prevent a malfunction due to 
noises.

4

Connect the DC 5V OUT connector of the monitor and 
the DC 5V/12V IN connector of the unit by using the 
SMF-700 or the cable supplied with the controller 
attachment stand such as BKM-37H.
Or connect the output cable of the AC adaptor supplied 
with the unit to the DC 5V/12V IN connector of the 
unit.

Connecting the Multiple Units with 
the LAN

The unit controls up to 32 monitors.  Up to four units are 
connected to one monitor in single mode.

The unit cannot control monitors in another subnetwork.

1

Turn off the MAIN POWER switch of the monitor 
before connecting the units.

2

Connect to the network by using a 10BASE-T/
100BASE-TX cable (shielded-type, optional).

 

• When an optional LAN cable is connected, use a 

shielded-type cable to prevent a malfunction due to 
noises.

• We recommend to use an optional switching hub 

with auto selection function (AUTO MDI/MDI-X) 
of a straight/cross cable.
When the switching hub without auto selection 
function is used, connect the monitor and switching 
hub with the straight cable, and the unit and 
switching hub with the cross cable.

Note

Note

Notes

BKM-16R
(this unit)

Monitor

LAN (10/100) 
connector

DC 5V/12V IN

connector

LAN (10/100) 
connector

Switching hub 
(recommended: with 
AUTO MDI/MDI-X 
function)

Monitor

LAN (10/100) 
connector

AC adaptor (supplied 
with this unit)

NETWORK switch

t

Set to LAN.

NETWORK switch

t

Set to LAN.

Содержание BKM-16R

Страница 1: ...MONITOR CONTROL UNIT BKM 16R OPERATION MANUAL English 1st Edition Revised 3 ...

Страница 2: ...interference at his own expense You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment All interface cables used to connect peripherals must be shielded in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules This device complies with Part 15 of the FCC Rules Operati...

Страница 3: ...ons 5 Location and Function of Parts 6 Front Panel 6 Rear Panel 9 Inserting Ejecting the Memory Stick 10 Notes on Memory Stick 10 Mounting the Unit in a Rack 12 Connections 12 Connecting the Monitor 12 Connecting the Multiple Units with the LAN 13 Specifications 14 Dimensions 15 ...

Страница 4: ...l connected monitors or put all connected monitors into the same setup and adjustment state Setup and adjustment with the Memory Stick You can use a Memory Stick to save and load monitor setup and adjustment data If your system includes more than one monitor you can use the Memory Stick to exchange data between monitors This makes it easy to put all monitors in your system into the same setup and ...

Страница 5: ...dently Monitor BVM A series BVM series except BVM A PVM L series PVM series except PVM L Available function Setup adjustment with Memory Stick a a a a CAPTURE a a Function assignment to function buttons a b a b SCAN a a a a H DELAY a a a a c V DELAY a a a a c MONO a a a a APT a a a Aperture modification adjustment a a a a COMB a a a CHAR OFF a a a COL TEMP a a a a 16 9 a a a a NATIVE SCAN a a a BL...

Страница 6: ...n frame d Function buttons Press to change the operation conditions for the monitor Each time the button is pressed the LED on the button turns on and turns off and the operation conditions are changed The LED may not turn on depending on the function You can assign other functions to the F1 to F16 buttons The button may not function due to the input signal For the limitations with each type of si...

Страница 7: ... button Press to cut R red G green and B blue respectively MARKER button Press to display all markers on the screen The marker display mode is set in the menu of the monitor CHROMA UP button Press to increase the chroma setting by 12 dB e Menu operation buttons f MONITOR I 1 switch Each time the switch is pressed the monitor is turned on or set in standby mode When several monitors are connected t...

Страница 8: ... monitor SINGLE SINGLE REMOTE GROUP ALL GROUP ALL SINGLE button Selects single connection mode The designated monitor is connected remotely The monitor ID number is displayed on all connected monitors when the button is held pressed GROUP button Selects group connection mode The monitor of the designated group is connected remotely The group ID number is displayed on all connected monitors when th...

Страница 9: ...able of the unit to peripheral device use a shielded type cable to prevent malfunction due to radiation noise To connect the unit to the LAN 10 100 connector of the monitor in 1 to 1 connection NETWORK switch is set to PEER TO PEER use a straight shielded type cable The connection speed may be affected by the network system b DC 5V 12V IN connector male Connect to the DC 5V OUT connector of the mo...

Страница 10: ... the Memory Stick in the correct direction Forcing the Memory Stick in the wrong way may damage it Insert only the Memory Stick into the Memory Stick insertion slot Attempting to insert other objects into the Memory Stick insertion slot may damage the product To eject the Memory Stick Notes on Memory Stick Available types of Memory Stick Memory Stick Memory Stick PRO Memory Stick Duo Memory Stick ...

Страница 11: ... at the same time This may cause damage to the product When you use Memory Stick Duo Memory Stick PRO Duo with this product be sure to insert it in the right direction Inserting it in the wrong direction may cause damages to the product Memory Stick Duo Memory Stick PRO Duo Memory Stick Micro and M2 adaptor should be kept away from small children to prevent them from accidentally swallowing it If ...

Страница 12: ...ze of the rack s holes Connections The illustrations of the monitor used in this manual are BVM E250 Note on connecting the cable to the DC 5V 12V IN connector Be sure to plug the female connector of the cable into the DC 5V 12V IN connector on the unit Connect the connector to the shape of the DC 5V 12V IN connector Connecting the Monitor Rack mount bracket BKM 16R this unit Rack mount attachment...

Страница 13: ...ing the Multiple Units with the LAN The unit controls up to 32 monitors Up to four units are connected to one monitor in single mode The unit cannot control monitors in another subnetwork 1 Turn off the MAIN POWER switch of the monitor before connecting the units 2 Connect to the network by using a 10BASE T 100BASE TX cable shielded type optional When an optional LAN cable is connected use a shiel...

Страница 14: ... 100 240 V 50 60 Hz DC OUT 12 V 3 A Current consumption 5 V DC 1 1 A 12 V DC 0 5 A Power consumption Approx 6 W Peak inrush current 1 Power ON current probe method 20 A 100 V 60 A 240 V 2 Hot switching inrush current measured in accordance with European standard EN55103 1 10 A 230 V Operating temperature 0 C to 35 C 32 F to 95 F Recommended 20 C to 30 C 68 F to 86 F Operating humidity 0 to 90 no c...

Страница 15: ...MEDIA EXTERNAL STORAGE SYSTEMS OR ANY OTHER MEDIA OR STORAGE SYSTEMS TO RECORD CONTENT OF ANY TYPE Always verify that the unit is operating properly before use SONY WILL NOT BE LIABLE FOR DAMAGES OF ANY KIND INCLUDING BUT NOT LIMITED TO COMPENSATION OR REIMBURSEMENT ON ACCOUNT OF THE LOSS OF PRESENT OR PROSPECTIVE PROFITS DUE TO FAILURE OF THIS UNIT EITHER DURING THE WARRANTY PERIOD OR AFTER EXPIR...

Страница 16: ... for use by the purchasers of the equipment described in this manual Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation ...

Страница 17: ...Sony Corporation BKM 16R WW 3 213 868 14 1 2008 ...