4-2
DNW-A22/A22P
Buttons and Switches for Operation
The main buttons and switches related to the operation of maintenance mode are as follows: The ordinary
functions of these buttons and switches and how to use them are described below.
1
Time data display area
The time data display area displays the menu (mode) No., menu title, selection item, status, or data.
The menu (mode) No. or selection item block blinks while the menu (mode) or selection item is
specified (not including the servo menu in the TAPE maintenance mode). For manual adjustment,
the data block blinks. In the state where the tape operation (PB, F FWD, and REW) can be per-
formed, the time data display area functions as an ordinary time counter.
There is a menu (mode) that contains insufficient information displayed in the time data display area.
Since the information displayed on the superimpose picture is easier to operate and check, usually use
a video monitor.
2
MENU button
Press this button in the maintenance mode to return to the screen (state) preceding by one step.
The maintenance mode is terminated if this button is pressed when the mode screen is displayed
(mode No. M0 or M2 blinks in a time data display area).
3
SET button
Press this button in the maintenance mode to select or execute the menu (mode) selected using a
8
search dial.
The maintenance mode can be activated when this SET button is pressed while pressing the
4
CTL/
TC/UB button in the setup menu mode with
0
DIP switch S1100-2 on the SS-63 board set to ON
(upper).
4
CTL/TC/UB button
The maintenance mode can be activated when the
3
SET button is pressed while pressing this
button in the setup menu mode with
0
DIP switch S1100-2 on the SS-63 board set to ON (upper).
5
RESET button
Press this button in the error logger mode to erase the recorded error log.
6
STOP button
The data value of an electronic volume control can be displayed only while the STOP button is
pressed in RF system automatic adjustment menu.
7
JOG button
The
8
search dial enters the JOG mode when this button is pressed (the lamp does not light in this
case). The data value or setting can be changed when the
8
search dial is turned while pressing this
button.
8
Search dial
Turn the search dial to specify the menu (mode) or selection item. An “
*
” mark moves on the video
monitor. In a time data display area, the display is replaced and the specified item blinks. (“JOG
DIAL” is displayed on the video monitor.)
The data value or setting can be changed when the search dial is turned while pressing the
7
JOG
button.
4-1. Overview of Maintenance Mode
Содержание Betacam SX DNW-A22
Страница 37: ...2 11 DNW A22 A22P 2 8 Location of Main Parts Front View Rear View ...
Страница 38: ...2 12 DNW A22 A22P 2 8 Location of Main Parts Top View of Cassette Compartment Top View of Mechanical Deck ...
Страница 49: ...2 23 DNW A22 A22P 2 14 Fixtures and Adjustment Equipment List 1 5 9 2 6 0 3 7 4 8 18 10 d l l S G L 6 6 d d ...
Страница 56: ......
Страница 76: ......
Страница 266: ......
Страница 272: ......
Страница 280: ......
Страница 284: ......
Страница 286: ...Printed in Japan Sony Corporation 2001 6 08 B P Company 1997 DNW A22 SY DNW A22P SY E 3 193 847 06 ...