1-9 (E)
BDX-D1000
S405, S406, S555, S556, S705, S706:
Output Reference Level Select switches
Select the reference level of the analog audio output CH1
to CH4 and monitor output LCH/RCH.
Channel
Switch
Reference Level
Factory Setting
+
+
+
+
+
4 dBm 0 dBm
_
_
_
_
_
3 dBm
_
_
_
_
_
20 dBm
CH1
S556
+
4
0
_
3
_
20
+
4
(F-10)
CH2
S555
+
4
0
_
3
_
20
+
4
(G-10)
CH3
S406
+
4
0
_
3
_
20
+
4
(J-10)
CH4
S405
+
4
0
_
3
_
20
+
4
(L-10)
L
S705
+
4
0
_
3
_
20
+
4
(MONITOR) (D-10)
R
S706
+
4
0
_
3
_
20
+
4
(MONITOR) (B-10)
1-8-2. DEC-99 Board (SUFFIX -14 and Higher)
n
.
The addresses on the board are shown by ( ) marks.
.
For the switches described “Factory use”, do not change
the factory setting.
S200-1 (A-5) : Program Mode Select switch
Selects the program mode.
ON : Single program mode
Used when a single-program stream is received.
OFF : Multi program mode
Used when a multi-program stream is received.
Factory setting : OFF (upper position)
S200-2 (A-5) : Factory use
Factory setting : OFF (upper position)
S200-3 (A-5) : Display Mode Select switch
Selects the display mode.
ON : Freeze mode
Freezes the picture that is shown just before the
received stream is interrupted.
OFF : Blackout mode
Turn the screen gradually into black when the
received stream is interrupted.
Factory setting : ON (lower position)
A side (Component side)
1
2
3
4
5
6
7
8
A
B
C
D
E
F
G
H
J
S200
S300
1 2 3 4 5 6
Factory setting
ON
S800
1
2
3
4
O
N
Factory setting
S600
S302
1
2
3
4
O
N
Factory setting
1
2
3
4
O
N
Factory setting