6.Command Specification
SONY AIT-2 Turbo drive SDX-550V series Ver.1.0
6-41
Maximum Burst Size:
This field defines the maximum amount of data that the drive shall transfer during a data
phase before disconnecting. This value is expressed in increments of 512 bytes. The default value is 0FBCh.
Note:
512
×
4,028(0FBCh)=2,062,336 bytes which means that the Maximum Burst Size is approximately equal to
SDX-550V Buffer size for SCSI side.
FAIR ARBITRATION:
This field indicates whether the drive shall use fair or unfair arbitration when requesting an
interconnect tenancy. Setting this field to 1 will enable the SCSI Bus Fairness protocol. Setting this field to zero will
disable it. The drive determines fairness by monitoring prior arbitration attempts by other SCSI devices. It shall
postpone arbitration for itself until all lower priority SCSI devices that previously lost arbitration either win a
subsequent arbitration or discontinue their arbitration attempts. It shall monitor the arbitration attempts of the other
SCSI devices and refresh the fairness register with the SCSI ID’s of any lower priority SCSI devices that lost
arbitration.
DTDC:
This field defines further restrictions on when a disconnect is permitted.
DTDC
Description
00b
01b
10b
11b
Data transfer disconnect control is not used. Disconnect is controlled by the other field in this page.
A target shall not attempt to disconnect once the data transfer of a command has started until all
data the command is to transfer has been transferred. The connect time limit and bus inactivity limit
are ignored during the data transfer.
Reserved
A target shall not attempt to disconnect once the data transfer of a command has started until the
command is complete. The connect time limit and bus inactivity limit are ignored once data transfer
has started.
6.7.2. Data Compression Control Page (0Fh)
The drive supports the Data Compression Control Page which has the following format:
Table 6-35: Data Compression Control Page
Bit
Byte
7 6 5 4 3 2 1 0
0
PS (0)
Reserved
Page Code (0Fh)
1
Page Length (0Eh)
2
DCE DCC
Reserved
3
DDE RED
Reserved
4
(MSB) Compression
Algorithm
7
(LSB)
8
(MSB) Decompression
Algorithm
11
(LSB)
12
Reserved
13
Reserved
14
Reserved
15
Reserved
Note:
If the drive does not support compression the drive will return Check Condition status, and the sense key will
be set to ILLEGAL REQUEST.
This page specifies the parameters for the control of the data compression capability of the drive.
DCE:
A Data Compression Enable (DCE) bit of one indicates that data compression is enabled. When this bit is set,
data sent to the device by the initiator shall be processed using the selected compression algorithm before being
written to the medium. A DCE bit of ZERO indicates that data compression is disabled.
Содержание AIT-SDX550
Страница 4: ...This page intentionally left blank ...
Страница 14: ...1 Introduction SONY AIT 2 Turbo drive SDX 550V series Ver 1 0 1 4 This page intentionally left blank ...
Страница 32: ...3 Installation SONY AIT 2 Turbo drive SDX 550V series Ver 1 0 3 8 This page intentionally left blank ...
Страница 42: ...4 Operation 4 10 SONY AIT 2 Turbo drive SDX 550V series Ver 1 0 This page intentionally left blank ...
Страница 54: ...5 SCSI Interface SONY AIT 2 Turbo drive SDX 550V series Ver 1 0 5 12 This page intentionally left blank ...
Страница 170: ...7 Drive Diagnostics 7 10 SONY AIT 2 Turbo drive SDX 550V series Ver 1 0 This page intentionally left blank ...
Страница 176: ...10 Appendix C 10 2 SONY AIT 2 Turbo drive SDX 550V series Ver 1 0 This page intentionally left blank ...
Страница 178: ...11 Appendix D 11 2 SONY AIT 2 Turbo drive SDX 550V series Ver 1 0 This page intentionally left blank ...
Страница 184: ...12 Appendix E SONY AIT 2 Turbo drive SDX 550V series Ver 1 0 12 6 This page intentionally left blank ...
Страница 196: ...14 Appendix G SONY AIT 2 Turbo drive SDX 550V series Ver 1 0 14 4 This page intentionally left blank ...
Страница 206: ...17 Appendix J SONY AIT 2 Turbo drive SDX 550V series Ver 1 0 17 4 This page intentionally left blank ...