Manual Supercom 646 GPRS rev. 04-02-2011
21
7.3.1 Instructions for a reading of the configuration and the device list
of the radio central
Cf. Annex A, page 33, for the detailed schema of the reading process.
1. Frame request “Rsp_1” with “REQ_UD2” (Adr.253).
Frame “Rsp_1”
Field
Frame bytes in hex (Note 1) Coding
Comment
Start,
L
ength
68,Le Le,68
C
ontrol
08
Respond with user data, RSP_UD
A
ddress
FD
C
ontrol
I
nformation
72
Variable structure respond
Identification number
xx xx xx xx
A, 32 bits
IdentificationNumber
Manufacturer ID
EE 4D
C, 16 bits "SON"
Manufacturer
Version of meter
0C
C, 8 bits
12
Version
Device type
0E
D, 8 bits
Bus / System component
DeviceType
Access number
xx
C, 8 bits
AccessNumber
Status
st
Ds, 8 bits
Status
Signature
00 00
C, 16 bits Not used
Signature
Detailed errors
02,FD 17,er er
D, 16 bits
ErrorFlags
0
0
0
0
Current date & time
04,6D,xx xx xx xx
F, 32 bits
DateAndTime
0
0
0
0
Day of week
01,FD 63,xx
C, 8 bits
1: Monday, 7: Sunday
DayOfWeek
0
0
0
0
Time Zone
01,FF 1F,xx
B, 8 bits
§, xx*15 min;
xx=4 means UTC+01:00
TimeZone
0
0
0
0
Battery use duration
03,FD 6C,xx xx xx
B, 24 bits [hour]
OperatingTimeBattery
0
0
0
0
Reading date 1
44,6D,xx xx xx xx
F, 32 bits
DateAndTime
0
0
1
0
Reading period 1
41,FD si,xx
C, 8 bits
[day | month]
StorageInterval
0
0
1
0
Reading options 1
41,FD 66,op
D, 8 bits
StateOfParameterActivat
ion
0
0
1
0
Reading date 2
84 01,6D,xx xx xx
xx
F, 32 bits
DateAndTime
0
0
2
0
Reading period 2
81 01,FD si,xx
C, 8 bits
[day | month]
StorageInterval
0
0
2
0
Reading options 2
81 01,FD 66,op
D, 8 bits
StateOfParameterActivat
ion
0
0
2
0
Reading date 3
C4 01,6D,xx xx xx
xx
F, 32 bits
DateAndTime
0
0
3
0
Reading period 3
C1 01,FD si,xx
C, 8 bits
[day | month]
StorageInterval
0
0
3
0
Reading options 3
C1 01,FD 66,op
D, 8 bits
StateOfParameterActivat
ion
0
0
3
0
Reading date 4
84 02,6D,xx xx xx
xx
F, 32 bits
DateAndTime
0
0
4
0
Reading period 4
81 02,FD si,xx
C, 8 bits
[day | month]
StorageInterval
0
0
4
0
Reading options 4
81 02,FD 66,op
D, 8 bits
StateOfParameterActivat
ion
0
0
4
0
Reading date 5
C4 02,6D,xx xx xx
xx
F, 32 bits
DateAndTime
0
0
5
0
Reading period 5
C1 02,FD si,xx
C, 8 bits
[day | month]
StorageInterval
0
0
5
0
Reading options 5
C1 02,FD 66,op
D, 8 bits
StateOfParameterActivat
ion
0
0
5
0
Date of last reading
C4 0F,6D,xx xx xx
xx
F, 32 bits
DateAndTime
0
0
31
0
Radio reading counter
C3 0F,FD 08,xx xx
xx
C, 24 bits
AccessNumber
0
0
31
0
Number of devices in the list
02,FD 22,xx xx
C, 16 bits
SizeOfStorageBlock
0
0
0
0
Number of devices with available
data
82 B0 30,FD 22,xx
xx
C, 16 bits
SizeOfStorageBlock
0
15
0
0
Remaining attempts of current
radio reading
01,FD 1E,xx
C, 8 bits
0: the radio reading is finished
Retry
0
0
0
0
S
ta
rt
<H
ea
d
er
>
U
se
r
D
a
ta
<
R
ec
o
rd
s>
<MbusRecord> XML attributes
P
ar
en
t t
ag
N
am
e
S
ub
U
ni
t
T
ar
iff
S
to
ra
ge
F
un
ct
io
n‡
Содержание Supercom 646
Страница 33: ...Manual Supercom 646 GPRS rev 04 02 2011 33 9 Annexe A 9 1 Reading process of the radio central configu ration...
Страница 34: ...Manual Supercom 646 GPRS rev 04 02 2011 34 9 2 Reading process of the radio central saved device list...
Страница 45: ...Manual Supercom 646 GPRS rev 04 02 2011 45 Notes...
Страница 46: ...Manual Supercom 646 GPRS rev 04 02 2011 46 Notes...
Страница 47: ...Manual Supercom 646 GPRS rev 04 02 2011 47 CD...