Product or/and customer logo

NFC interface

Typ of product (SQ1S = single jet ; SQ1M = measuring capsule)

Year of calibration

MID Homologation N° 

Pressure range

Part N°

Radio communication (Sontex 433 MHz, wM-Bus 868 MHz, LoRaWAN 868 MHz)

CE marking and test laboratory N°

MID-Measuring range class

Temperarure T30 or T90

Flow rate 

Drinking water marking (country specific)

Producer address

ID and Serial N°

A

B

C

D

E

F

G

H

I

J

O

L

6. Device labelling

K

L

M

N

A

B

C

D

E

F

G

H

I

J

K

M

N

O

Содержание SQ1M

Страница 1: ...Instruction for Use Superaqua 1...

Страница 2: ...ce dimensions Multi jet measuring capsule 9 5 1 Mounting of measuring capsule 9 6 Device labelling 10 6 1 Display 11 6 2 Delivery mode 11 6 3 Switch to operating mode radio activation 11 6 4 Radio act...

Страница 3: ...for Superaqua 1 will be explained as a note in the current man ual s different sections 1 2 Target groups This documentation is intended for the system operator and the installer 1 3 Ablage des Dokume...

Страница 4: ...n observance of which may result in damage to property Reference Information that is important for a specific topic or goal but not relevant to security Documentation Reference to documentation Help H...

Страница 5: ...nel qualification The water meter may only be installed or replaced by qualified personnel for sanitary heating and air conditioning technology 2 2 Intended use Water meters are used for recording the...

Страница 6: ...6 Instruction for use Superaqua 1 3 Scope of delivery Transport Storage Cleaning Tools MB2 Single jet Measuring capsule...

Страница 7: ...7 Instruction for use Superaqua 1 4 Dimension Single jet 4 1 Mounting instruction for single jet water meter...

Страница 8: ...8 Instruction for use Superaqua 1...

Страница 9: ...9 Instruction for use Superaqua 1 5 Dimension Multi jet measuring capsule 5 1 Mounting instruction for multi jet measuring capsule D1 75 mm D2 70 mm H von ca 35 bis 62 mm...

Страница 10: ...MID Homologation N Pressure range Part N Radio communication Sontex 433 MHz wM Bus 868 MHz LoRaWAN 868 MHz CE marking and test laboratory N MID Measuring range class Temperarure T30 or T90 Flow rate...

Страница 11: ...io Opening a water tap for a few seconds triggers the switchover of the water meter to the operating mode The device display changes and only then the radio is also started A standard minimum volume o...

Страница 12: ...6 6 Device display loop Display Display time Example 10 s Consumption 36 214 m3 Current flow rate 15 l h 3 s optional Set day value 175 m3 Check number c85 Set day 01 01 Min 1 s can be exten ded Firm...

Страница 13: ...op of the battery Attention The device must be replaced Overview of event and error messages For various analyses it is very helpful to examine the chronological course of events To make this possible...

Страница 14: ...Installer read and change settings Verifier read and change metrological parameters The installer password is 0x1234 The installer password can be changed or disabled 7 1 Volume stored data The curre...

Страница 15: ...dio telegram C1 or T1 transmission power 14 dBm 25 mW LoRaWAN Frequency 868 MHz bidirectional transmission power 14 dBm 25 mW 9 Technical data Dimension Single Jet lenght L height H Multi Jets measuri...

Страница 16: ...tore lithium batteries protected from moisture do not heat above 100 C or throw into fire Do not short circuit open damage or charge lithium batteries Always keep lithium batteries out of the reach of...

Страница 17: ...17 Instruction for use Superaqua 1...

Страница 18: ...32 488 30 00 sontex sontex ch www sontex ch 21 06 Technical support For technical support contact your local Sontex agent or Sontex SA directly Hotline Sontex support sontex ch 41 32 488 30 04 Techni...

Отзывы: