Sontay GL-CO-RFG65 Series Скачать руководство пользователя страница 5

Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or 

expense resulting from errors or omissions. In the interest of technical improvement, this specification may be altered without notice. 

 

Page 5 of 5 

UK Sales Tel: 0845 345 7253 

International Tel: +44 1732 861225 

For the latest information and product updates, register at www.sontay.com 

GL-CO-RFG65x 

Issue: 5.4 

Date Of Issue: 28/10/2008 

© 2008 Sontay Limited. All rights reserved. 

Example Connections (continued) 

GL-CO-RFG653, 230Vac Supply: 

 
GL-CO-RFG653, 12V Supply: 

 

 

 
 
 
 
 
 
 
 
 
 

 

Содержание GL-CO-RFG65 Series

Страница 1: ...2g DIN 40046 Relay outputs 2 x SPDT 250V 5 1 A Housing dimensions 105 x 115 x 70mm Housing materials Cover ABS Base Nylon Housing protection IP40 Panel mount housing dim 142 x 142 x 125mm Sensor dimensions 77 x 77 x 44 Sensor material Nylon Sensor protection IP44 Ambient Storage temp 25 to 60 C Operating temp 0 to 45 C RH Class F Din 40040 Country of origin Italy GL CO RFG651 1 Channel gas leak al...

Страница 2: ...le terminal Use external junction boxes if necessary 7 Replace the cover on the base using the 4 screws pro vided if panel mounting fix to panel door using the panel mounting kit Panel Mount Cut Out Panel cutout 138 x 138 0 5 Link Functions M F1 No link Internal buzzer enabled Linked Internal buzzer disabled F2 F3 No link Relay normally energised when no gas present Linked Relay normally de energi...

Страница 3: ...5 to 2 minutes with the FAULT and ALARM LEDs flashing to allow the sensor to stabilise When the gas concentration exceeds the pre alarm thresh old the ALARM LED blinks When the gas concentration exceeds the alarm threshold after a delay of about 20 seconds The internal buzzer will sound if enabled The ALARM LED switches ON Activates the operational control Self diagnostics In the event of a fault ...

Страница 4: ...861225 GL CO RFG65x Issue 5 4 Date Of Issue 28 10 2008 2008 Sontay Limited All rights reserved Front Panels Example Connections 1 Sensitivity potentiometer 2 Power supply LED 3 Fault LED 4 Alarm LED 5 Reset button Dimensions Basic operation GL CO RFG652 230Vac Supply ...

Страница 5: ...terest of technical improvement this specification may be altered without notice Page 5 of 5 UK Sales Tel 0845 345 7253 International Tel 44 1732 861225 For the latest information and product updates register at www sontay com GL CO RFG65x Issue 5 4 Date Of Issue 28 10 2008 2008 Sontay Limited All rights reserved Example Connections continued GL CO RFG653 230Vac Supply GL CO RFG653 12V Supply ...

Отзывы: