Buff-n-Dry Machine
– Owner’s
Manual
© SONNY’S The CarWash Factory
SonnysDirect.com
This document is
confidential and proprietary to SONNY’S and cannot be used, disclosed or
Page 26 of 31
duplicated without prior written consent. Content, prices, and availability subject to change without notice.
9.23.2021
10013911-R3.docx3
Speed and Torque Adjustment
Electric
a. The speed can be adjusted on the VFD (Variable Frequency Drive).
Note: it is not recommended to run brushes above the RPMs listed in table 1a and 1 b
•
To increase the speed, adjust the Hertz on the VFD to a higher number.
•
To decrease the speed, adjust the Hertz on the VFD to a lower number.
b. The Overload on the Motor Starter protector(s) must be set at the lowest level to allow for
operation.
c. Adjust the amps in accordance with the motor(s) name plate.