Sonnen eco 8 Скачать руководство пользователя страница 4

 
 
 
 
 
 

 

 

 

 

 

S o n n e n   A u s t r a l i a   P t y   L t d  

L e v e l   2 0 ,   T o w e r   A  

821 Pacific Highway, Chatswood 

NSW  

ACN 611 337 547 

0408 802 388 

[email protected] 

 

 

 

L1 = 14 for the eco 8.03 (3-phase) 

 

L2 = 15 for the eco 8.03 (3-phase) 

 

L3 = 16  for the eco 8.03 (3-phase) 

► Make sure that the meter LED is on 
► Make sure that the RS485 connections 
within the CAT.5e Inline Coupler are 
seated correctly 
► Make sure that the Modbus cable from 
the Inline Coupler to the Sonnen Modbus 
(XMOD) connection port is connected 
correctly 
► If the Inline Coupler has not been used 
then ensure that the correct connections 
have been made into the green WAGO 
strip connector on the meter is wired as: 

 

A-     = White/blue 

 

B+    = Blue  

 

GND = Brown  

 

Battery is not discharging 

Values on the App or 
Online Portal are on zero 
or a static SOC value 

► Make sure that the Meter is operating 
correctly 
► Make sure that the CT’s are located in 
the correct positions and are facing the 
correct power flow direction 
► Make sure that Batteries DC cables are 
connected correctly 
► Make sure that Battery BMS is 
connected correctly 
► Make sure that Battery voltage p/module 
is correct and each are within 1V of each 
other 
► Make sure that Overall connected 
battery voltage is correct 
► Make sure that Battery addresses are 
set correctly 
► Make sure that Battery Modbus address 
is set correctly 
► Make sure that the AC connection is 
wired correctly 
► Make sure that Correct AC phasing is 
wired on 3-phase (eco 8.03) systems 
 

Battery stopped discharging and re-
charging 

Values on the App or 
Online Portal are static 

► Restart the Sonnen unit, follow 
shutdown and startup procedure as the unit 
may require a physical restart after a 
firmware update (uncommon). 
► Make sure that the Meter is operating 
correctly 
► Make sure that the CT’s are located in 
the correct positions and are facing the 
correct power flow direction 
 