TS001 

– Sonnen eco 8 – Trouble Shooting Guide 

 
This guide covers both the eco 8.2 single phase series products as well as the eco 8.03 three phase series, differences 
between each will highlighted within the points raised if necessary. 
 

Issue 

Reason 

Solution 

 

No local internet connection.  

 
The storage system is not displayed on 
the local network   
(

https://finde-meine.sonnenbatterie.de/

 

No connection between 
the storage system and 
the local router. 

► Make sure that the Ethernet line 
between the storage system and the 
Router of the home network is correctly 
connected. 
 
► Make sure that the Ethernet lights are 
on at the PLC (rear of door) 
 
► Remove Z-Wave USB (Short term 
solution) 
 

No internet connection.  

 
(the storage system is not displayed at 
the Internet portal 

https://meine.sonnenbatterie.de

 

No connection between 
the storage system and 
the server. 

► Make sure that the Ethernet line 
between the storage system and the 
Router of the home network is correctly 
connected. 
 
► Make sure that the Router of the home 
network allows connections on the 
following ports: 
 
   

TCP-Port   Service 

 
   22              SecureShell (ssh) 
   37              Time Server (ntp) 
   80              Online-Check (http) 
   222 VPN    Server Connection ssl 
   232 VPN    Backup 
   443             App-Control (https) 
 
   

UDP-Port   Service 

 
   1196           Server Connection ssl 
 

System will not start, F1 trips after 
10-15 seconds  
 

Internal safety function to 
protect battery modules 

►Remove all orange power connectors 
 
► Check if all DC connection cables and 
BMS cables are connected and plugged 
correctly 
 
► Check the voltage of each module: 
measure the voltage between right contact 
of the opened orange power connector and 
the minus pole ensuring all modules in the 
system are in a range of 1V. 
 

Отзывы: