Mounting | 4
KD-492 | 22320 | EN | X02
15 / 40
4.3 Selecting the installation location
4.3.1 Requirements for the installation location
Observe the required ambient conditions (see Technical data [P. 8]).
4.3.2 Observe minimum and maximum distances
• The Backup-Box should be mounted to the right or left of the storage system.
Install the Backup-Box at the same level as the top edge of the storage system, if pos-
sible.
15
5
10 - 50
15
10
30 - 50
Illustration 3: Distances to the Backup-Box
(Figure not to scale - all specifications in centi-
metres)
Observe the specified
maximum
distances
between the Backup-Box and the storage sys-
tem, so that the length of the pre-assembled
and supplied cables is sufficient.
Observe the specified
minimum
distances to
the storage system and neighbouring objects,
so that there is sufficient heat dissipation, the
door can be opened easily and there is suffi-
cient space for installation and maintenance
work.
4.4 Mounting the Backup-Box
4.4.1 Requirements for mounting material
Use only screws with the following properties:
max. 6 mm
max. 15 mm
8 mm
Illustration 4: Parameters of the screw used
• Screw head diameter: max. 15 mm
• Screw diameter: 8 mm
• Hight of screw head: max. 6 mm
• The screw lengths and the wall plugs used must be suitable for the nature of the wall.
4.4.2 Drilling the holes
A drilling template is part of the packaging of the Backup-Box. Therewith it is
easier to mark the position of the holes on the wall. Please use the holes
marked as ‘base cabinet’ for the Backup-Box.