Common Offline Failures and Countermeasures
The MP5S Writer prompts for different types of failures in offline mode;
For different information, the countermeasures are shown in the following table:
No.
Type and
information of
failure
Countermeasure
1
ERR0
A: Remove MCU and the transfer board, reset the writer, and then check whether the alarm is
on; if there are still alerts, please contact with the supplier or SONiX;
B: Please confirm whether VXX/VPP of the Writer is within the range;
C: Please confirm that the type of the transfer board is consistent with the MCU model;
2
ERR1
Please confirm the used MCU is blank;
3
ERR2
A: Confirm that MCU is well contact with the MP5S Writer;
B: Confirm that the used cable is shorter than 15cm;
C: Confirm the used socket is in good contact, please clean and replace regularly;
D: There are open/short-circuit and other problems in some pins of the placed MCU, please
replace;
4
ERR3
A: Confirm the writing file is consistent with the data of MCU to be written;
B: Confirm that MCU is well contact with the MP5S Writer;
C: Confirm that the used cable is shorter than 15cm;
D: Confirm the used socket is in good contact, please clean and replace regularly;
E: There are open/short-circuit and other problems in some pins of the placed MCU, please
replace;
5
ERR4
The data stored in the writer is abnormal, please redownload the writing file;
6
ERR5
MCU of other model is placed, please place the correct MCU;
7
ERR6
A: Please place MCU;
B: MCU of other model is placed, please replace;
C: MCU placement or direction is incorrect;
D: There are open/short-circuit and other problems in some pins of the placed MCU.