Notes
•
These figures (*) are for readers powered from the controller. The cable distances
can be increased to 1650’ / 500m by locally powering the readers.
•
Locally powered readers must be connected to a UL 603 power limited Class 2
supply for US, or a ULC S318 power limited Class 2 supply for Canada.
•
If you use 22AWG / 0.34mm² cables, twist the wires and double them over before
inserting them in the crimps.
•
Maximum cable distances will be less for readers which have been set to give
Wiegand output.
Specification
Current
Power
Reader Range
< 100mA
12V — +24V
Up to 4.0” / 100mm
Temperature
Storage
Operating
-40°C — +66°C / -40°F — +151°F
-40°C — +66°C / -40°F — +151°F
Humidity
Operating for 24 hours
Tested at 93% for ULC S319.
10-85% RH @ 30±2°C / 85±4°F
Ingress Protection
IP65 after installation — evaluated by lab separate from UL. Installer must adequately seal any
connections made.