Redbox User Handbook No 1
23
In Master sync mode, switch positions 0 – 5, the digital output sample rate is simply set by,
and locked to, the internal on-board clock generator. No sync signal is used or required.
In Auto sync mode, switch positions 6– B, the digital output sample rate follows the sync
input. When the sync signal is not present the output sample rate will be set by, and locked
to, the internal on-board clock generator at a frequency determined by the switch position.
In Auto-Lock sync mode, switch position C, no output will be generated until lock is
achieved with a sync signal. The digital output sample rate now follows the sync input. If the
sync signal is removed then the output sample rate will be set by, and locked to, the internal
on-board clock generator at the closest frequency available to the previous sync input.
In Slave sync mode, switch position D, the digital output sample rate follows the sync input.
When the sync signal is not present the digital output is turned off.
Fig 3-5, also printed on the top of the unit, summarises the rotary switch settings and shows
the sample rate generated by the internal clock generator in master and auto sync modes.
Frequencies and Sync Modes
Rotary
Switch
Number
Mode
Sample
Frequency
(kHz)
0
Master
32
1
Master
44.1
2
Master
48
3
Master
96
4
Master
96
5
Master
96
6
Auto
32
7
Auto
44.1
8
Auto
48
9
Auto
96
A
Auto
96
B
Auto
96
C
Auto Lock
-
D
Slave
-
Fig 3-5: RB-SC1 Frequency and Sync Rotary Switch Settings
DIGIT
AL A
UDIO C
ONVERTERS - RB
-SC1
3
DIGITAL AUDIO CONVERTERS
Содержание Redbox RB Series
Страница 86: ...70 Redbox User Handbook No 1...
Страница 158: ...142 Redbox User Handbook No 1 N OT E S NOTES...
Страница 159: ...Redbox User Handbook No 1 143 NOTES NOT ES...
Страница 160: ...w w w sonifex co uk t 44 0 1933 650 700 f 44 0 1933 650 726 sales sonifex co uk...