29
Webserver 6
Digital Share Master
- Allows 2 x DHY-04 units to share a digital audio
connection by connecting the right hand channel of the digital audio input
and output data to the Conference Port.
Digital Share Slave
- Retrieves the incoming audio and presents outgoing
audio to the Conference Port.
Force Analogue Output
The Main Output of the unit will follow the input type unless this option is
selected when the output is always analogue.
Note it is not possible to output digital audio without a digital input being
present.
Save Cancellation Coeffs
To tune the system we recommend pre-loading the cancellation coefficients
to allow the unit to optimise the speed of the echo cancellation. Use this
option to save the current values after a call has been made with good
cancellation.
A call to a telephone that has a muted microphone pick-up whilst still
sending audio from the DHY-04 is ideal for this.
NOTE: If the DHY-04 settings for Country Code or Echo Length are changed
then the coefficients will be cleared.