![sonible missing link ml:1 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/sonible/missing-link-ml-1/missing-link-ml-1_user-manual_1320544009.webp)
ml:1 user guide
9
The test signal is a multitone (a combination of harmonic sinusoidal components) and will
be routed to the analog outputs. To trigger the test tone you have to hold the switch for
more than 1 second. This delay prevents unwanted activation of the signal generator
during shock, heavy vibration or faulty operation.
test tone signal
waveform:
harmonic multitone f
0
=130Hz±10Hz
amplitude:
-22dBu (at full battery charge)
The following plot shows the approximate spectrum of the test tone signal.
130Hz
260Hz
520Hz
1040Hz
2080Hz
8320Hz
log frequency
Содержание missing link ml:1
Страница 1: ...user guide ...