background image

User Manual

LC-RL-8-W

Wall Mount 8CH RELAY Controller

Содержание LC-RL-8-W

Страница 1: ...User Manual LC RL 8 W Wall Mount 8CH RELAY Controller...

Страница 2: ...f this publication may be copied or reproduced without prior written consent FCC Statement This equipment generates uses and can radiate radio frequency energy and if not installed and used in accorda...

Страница 3: ...e or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose you to dan...

Страница 4: ...ower Requirements 3 2 3 Connections 3 2 4 Controls and Indications 3 2 5 Mechanical specifications 4 2 5 1 Enclosure 4 2 5 2 Environmental 4 2 5 3 Dimensions and weight 4 3 APPLICATION AND WIRING DIAG...

Страница 5: ...s 8 Channels RELAY Controller standard type 10A per channel Power switching Used in non dimmable lighting control screen control up to 0 5Hp motor etc Supports 16 scenes with internal memory Low volta...

Страница 6: ...nctionality of these switches is to navigate through the channels manually along with channel status indication LEDS 1 4 Loads Two pin detachable terminal blocks on the rear side for each channel to c...

Страница 7: ...s CHANNELS 1 8 4 2 pin 5 08 mm detachable terminal blocks with SPST relay switch circuit 10A per channel LV TRIGGERS G 1 8 1 5 pin 5 08mm detachable terminal block to provide low voltage trigger to ea...

Страница 8: ...echanical specifications 2 5 1 Enclosure Wall Mount dark Gray metal sheet enclosure 2 5 2 Environmental Operating Temperature 0 to 45 C 2 5 3 Dimensions and weight Parameter Value Unit Height 4 13 Inc...

Страница 9: ...LC RL 8 W User Manual Sonetonix 5 3 Application and wiring diagram...

Страница 10: ...ing mode Step 3 The default S NET ID will be displayed in terms of WDT LED blinking sequence Step 4 Press the 2 switches on front panel to set the S NET ID number Step 5 After choosing a suitable ID p...

Страница 11: ...e under Command Description Response Get Device Info ID F2 F5 ID Device Type Device model F5 Get New Device Info F0 F2 F5 ID Device Type Device model F5 Set New Device ID FE ID F3 new ID FD F5 ID ch1...

Страница 12: ...2 channels in scene FE 01 F7 02 05 01 01 00 00 04 01 00 00 FD Recall scene 5 for device ID 01 FE 01 F8 05 FD Set multiple control command to ON load 1 and Off load 2 after 5 seconds ID 01 FE 01 F6 02...

Страница 13: ...r removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warranty...