OPERATING MANUAL MIC-2505 version 1.01 

18 

10.2 

Optional accessories 

 

Additionally, the following items that are not included in the scope of standard equipment 

can be purchased from the manufacturer or the distributors: 

 

WAKRORE20K05

 

 

 

  5kV crocodile clip, cat. IV 1000V red 

 

WAPRZ005BLBBE5K

 

  5m shielded lead, black, cat. IV 1000V 

 

WAPRZ005REBB5K

 

  5kV

 

lead

5m, red, with banana plugs 

  

WAPRZ005BUBB5K

 

  5kV lead, 5m, blue

 

terminated with ba-

nana plugs 

 

WAPRZLAD12SAM

 

 

 

  Cable for charging the accumulator 

package from the car cigarette lighter 

socket (12V) 

 

WASONBLOGB2

 

 

  blade probe with banana socket black 

 

WAPRZ010BLBBE5K

 

  10m shielded lead, black, cat. IV 1000V 

 

WAPRZ010REBB5K

 

  5kV lead, 10 m, red, with banana plugs 

 

WAPRZ010BUBB5K

 

  5kV  lead, 10m, blue terminated with ba-

nana plugs 

 

WAPRZUSB

 

 

 

  USB interface cable  

 

LSWPLMIC2510

 

 

 

  calibration certificate 

 

 

 

Содержание MIC-2505

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...OPERATING MANUAL INSULATION RESISTANCE METER MIC 2505 SONEL SA ul Wokulskiego 11 58 100 widnica Version 1 01 17 02 2012...

Страница 6: ...ersion 1 01 2 MIC 2505 meter is a modern easy in use and safe measuring device Please acquaint yourself with the present manual in order to avoid measuring errors and prevent possible problems related...

Страница 7: ...ER SUPPLY 13 5 1 MONITORING OF THE POWER SUPPLY VOLTAGE 13 5 2 REPLACING RECHARGEABLE BATTERIES 13 5 3 CHARGING RECHARGEABLE BATTERIES 13 5 4 GENERAL PRINCIPLES REGARDING USING NIMH RECHARGEABLE BATTE...

Страница 8: ...ipment in rooms with special conditions such as fire or explosion hazard It is unacceptable to operate the following a damaged meter which is completely or partially out of order a meter with damaged...

Страница 9: ...ETUP button pressed Use and buttons to set the auto off time or cancel auto off function horizontal lines Press SEL button to enter the setting of no minal network frequency Use and buttons to set the...

Страница 10: ...IC 2505 version 1 01 6 Use and to set Ab1 Ab2 parameters or PI DAR Press ENTER to display the measurement screen approving introduced changes or press ESC to go to the measurement scre en without vali...

Страница 11: ...each other and the probe crocodile clips because such a contact may cause the flow of surface currents resulting in additional error in measu rement results Set the rotary switch of function selection...

Страница 12: ...pressed a triangle with an exclamation mark will be displayed in dicating about automatic measurement now the buttons may be released In or der to interrupt the measurement press START or ESC View of...

Страница 13: ...UISO voltage is stabilized Symbol LIMIT means operation with limited converter current If this condition persists for 20 se conds the measurement is interrupted If the timer reaches characteristic po...

Страница 14: ...measurement when voltage previously reached the nominal value LED is lit in red two tone acoustic signal During the measurement AC voltage appeared or the ob ject cannot be discharged for 30 seconds...

Страница 15: ...ors of the cable at taching to G terminal other conductors that do not take part in the measurement 3 3 Voltage measurement Set the rotary switch of function selection at U position Connect the meter...

Страница 16: ...eter LED is lit in red two tone acoustic si gnal Voltage is higher than acceptable Immediately disconnect the test leads 4 Software updates Turn on the meter holding ENTER and SETUP buttons de pressed...

Страница 17: ...ighter socket using an optional charger WARNING If the test leads are left in the terminals during replacement of the batteries the re is a risk of electric shock with a dangerous voltage To replace t...

Страница 18: ...aximum capacity after being formatted 2 3 charge discharge cycles The most important factor which influ ences the lifetime of rechargeable batteries is the level of their discharge The deeper the disc...

Страница 19: ...case of storage of the device the following recommendations must be observed Disconnect all the test leads from the meter Clean the meter and all its accessories thoroughly In the case the meter is to...

Страница 20: ...um values of the measured resistance depending on the test voltage are presented in the table below For other voltages the range limits may be read from the chart below Voltage Test range 500V 500G 10...

Страница 21: ...non standard condi tions and for metrological laboratories for the purpose of calibration Significant parameter Designation Additional uncertainty Position E1 0 Supply voltage E2 0 BAT is not lit Temp...

Страница 22: ...cat IV 1000V WAPRZ005REBB5K 5kV lead 5m red with banana plugs WAPRZ005BUBB5K 5kV lead 5m blue terminated with ba nana plugs WAPRZLAD12SAM Cable for charging the accumulator package from the car cigare...

Страница 23: ...urer of the device and provider of warranty and post warranty service SONEL S A ul Wokulskiego 11 58 100 widnica Poland tel 48 74 858 38 60 fax 64 74 858 38 09 E mail export sonel pl Web page www sone...

Страница 24: ...OPERATING MANUAL MIC 2505 version 1 01 20...

Страница 25: ......

Страница 26: ......

Отзывы: