User Manual for the Type 8370
WSM 6+ Transponder
UM-8370
Issue A Rev 1
13
Section 4 – Installation
4.1 Introduction
Before installing the equipment, make sure
Section 2 – Safety
is read and fully understood.
4.2 Pre-Use Checks
Before installation, checks should be carried out to make sure the WSM 6+ is serviceable and ready
for use. These checks include:
•
Check the Pressure Relief Vent Valve; refer to
Section 4.2.1 “Checking the Pressure
.
•
In necessary, charge the battery; refer to
Section 4.2.2 “Charging the Battery”
.
4.2.1 Checking the Pressure Relief Vent Valve
A Pressure Relief Vent Valve is provided to reduce the build-up of gas inside the WSM 6+ caused
by the battery charging process.
Check the Pressure Relief Vent Valve is flush with the endcap. If the Pressure Relief Vent Valve is
not flush it could indicate a pressure build-up during previous operations due to a fault developing in
the battery pack.
Note
Refer to
Warnings
in
Section 2 – Safety
“
Faulty Battery Pack
”.
Figure 4-1 WSM 6+ Pressure Relief Vent Valve
Pressure Relief Vent Valve