STEP 12
OPERATING THE EQUIPMENT
USING THE iWAND TO SET CONFIGURATION
Once an instrument has been configured by the iWAND 6G Configurator software, the
settings will be automatically downloaded to the iWAND ready for a synchronisation
process to be performed.
Disconnect the iWAND from the PC and move to the location of the 6G equipment to be
configured.
Configurations for multiple instruments can be held by the iWAND at the same time.
1
On the iWAND home screen select
Set configuration
from the main menu.
2
Hold the iWAND acoustic transducer firmly against the transducer of the instrument
and maintain contact throughout the configuration.
18 Configuration changes made to an instrument on the iWAND 6G Configurator
Software must now be transferred to the instrument.
OPERATING THE iWAND 6G CONFIGURATOR SOFTWARE
3
Press
ENT
to start the configuration process.
4
When the iWAND has found the instrument, the address will appear.
5
The iWAND will detect if a new configuration is pending based on the UID, and
sends the appropriate setting changes to that unit.
6
If the iWAND detects a
Release Mechanism
or
Sensors
are fitted to the
instrument, it will ask if a Release Test or Sensor test is required. Refer to
Get
Configuration
(Step 4) for the Release and Sensor Test procedure.