Section 12 – Technical Specifications
28
Section 12 – Technical Specifications
12.1 Technical Drawing
Figure 12-1 Lodestar Outline Dimensions (mm)
12.2 Specifications
12.2.1 Performance
Parameter
Specification
Heading Accuracy
0.04° to 0.1° Secant latitude RMS
Settling time
Better than 5 minutes
Follow-up speed
>500° per second
Roll and pitch range
-90° to +90° (no physical limit)