Sonance Sonamp 875D SE Скачать руководство пользователя страница 4

4

SONAMP

®

875D SE 8-CHANNEL AMPLIFIER

Introduction

Thank you for purchasing the Sonance Sonamp

®

875D SE power amplifier. The 875D SE will provide you with many years

of home entertainment enjoyment. This manual will teach you all about your new amplifier’s many innovative features and
will show you how to get the very best performance from your amplifier. Please read it thoroughly.

Design and Features

Power

The Sonamp

®

875D SE is a hybrid amplifier that

combines  digital amplification with analog
power supplies. Its Class T amplifier with Digital
Power Processing™ technology delivers the
high efficiency of digital (Class D) amplification
with the superior sound quality of analog (Class
AB) amplifiers. This allows the 875D SE to deliver high power (75 watts RMS per channel @ 8 ohms x 8 Channels) in an
exceptionally small (2U rack height) package. And unlike conventional digital amplifiers which cannot operate in bridged
configuration, the 875D SE’s Class T circuitry allows you to operate it with any of its four pairs of channels in a bridged
mode, providing 300 watts x 4 channels into an 8-ohm load. Four independent power supplies (one for each zone) supply
plenty of current, so each zone can maintain full performance regardless of how hard any other zones are being driven.

BBE

®

Sound Enhancement

The Sonamp 875D SE incorporates BBE

®

Sound Enhancement. The BBE process improves the presence and detail of speakers,

especially at lower listening volumes, improving the sound quality of your music — especially distributed audio systems
playing background music. BBE also restores clarity and definition (or focus) to spoken voices, which makes paging 
systems easier to understand without having to run them at high volumes. Each zone in the 875D SE has individual 
controls that let you set the BBE enhancement for that zone to +9dB, +6dB or OFF. The factory default setting is +6dB.

Inputs and Triggers

Multiple audio input connections (D

IRECT

, L/R & A

UX

) and buffered line outputs make your 875D SE extremely flexible, so

you can connect the amplifier in a variety of ways depending on your particular system’s configuration. The Illustrations on
pages 15 – 20 show the 875D SE being used in several different possible system configurations. Each zone has its own 12V
input and output triggers and defeatable auto-on signal sensing that can automatically turn the amplifier ON. Recessed
front-panel controls are tamper-resistant, and let you adjust each channel’s input level and each zone’s auto-on sensitivity.
Front-panel LEDs tell you if the 875D SE’s power is on or off, if each Zone is on or off, and the BBE status and fault status
for each zone.

Serial Control Capability

The 875D SE’s RS-232 connection lets you use a variety of 3rd-party serial control systems to control the amplifier. 
The serial control provision lets you control almost all of the 875D SE’s functions, and also lets you monitor the amplifier’s
operation from a remote location.

Figure 1: Sonamp

®

875D SE

Содержание Sonamp 875D SE

Страница 1: ...INSTRUCTION MANUAL SONAMP 875D SE 8 CHANNEL AMPLIFIER...

Страница 2: ......

Страница 3: ...ply only of the type described in the operating instructions or as marked on the unit 1 11 1 G Gr ro ou un nd di in ng g o or r P Po ol la ar ri iz za at ti io on n Precautions should be taken so that...

Страница 4: ...e presence and detail of speakers especially at lower listening volumes improving the sound quality of your music especially distributed audio systems playing background music BBE also restores clarit...

Страница 5: ...L S N 1 2 3 4 5 6 7 8 BRIDGED 8 MIN BRIDGED 8 MIN BRIDGED 8 MIN BRIDGED 8 MIN NORMAL BRIDGED NORMAL BRIDGED BRIDGED CH3 CH4 BRIDGED CH5 CH6 BRIDGED CH7 CH8 BRIDGED CAUTION REPLACE WITH THE SAME TYPE A...

Страница 6: ...amp 875D SE on a level surface in an upright position out of direct sunlight and away from windows through which rain may enter Situate the amplifier away from heat sources such as hot air ducts or ra...

Страница 7: ...on n e et tc c NOTE If you re serial controlling the 875D SE you can poll the amplifier at any time and its internal temperature will be reported to the control device Over Current Protection If an ov...

Страница 8: ...and from the amplifier s Power Cord Connector 2 Insert a flat blade screwdriver or similar tool into the empty Power Cord Connector socket and gently pry the fuse holder out of its socket 3 Install th...

Страница 9: ...ovide the most flexible configuration options of any multichannel amplifier Settings are changed by setting the switches either OFF left or ON right DIRECT Assign channel to the channel DIRECT input s...

Страница 10: ...ts but be sure to check local codes governing wire that may be installed within walls or ceilings Different brands of wire can have different characteristic sounds and some may be more compatible with...

Страница 11: ...ce e 1 Move the NORMAL BRIDGED switch for the zone to the BRIDGED position see Figure 11 2 Strip no more than of insulation from the speaker leads Twist the strands or tin the exposed wire with solde...

Страница 12: ...ensitivity ranges from 5mV ch in the full clockwise position to OFF AUTO ON will not trigger in the full counter clockwise position In the AUTO ON mode the zone will remain ON for approximately 3 minu...

Страница 13: ...ent is not applied If the OFF ON switch is set to ON BBE enhancement is applied according to the set ting of the LOW HIGH switch LOW 6dB of BBE enhancement HIGH 9dB of BBE enhancement NOTE The factory...

Страница 14: ...load at w ww ww w s so on na an nc ce e c co om m Please check the website for information about compatibility with additional controllers Connecting the 875D SE to a Serial Control Device The 875D SE...

Страница 15: ...evel than expected Zone Mute Mxy cr x Zone 1 4 or G Global y State 0 Mute Off 1 Mute On Channel Mute MCxy cr x Channel 1 8 or G Global y State 0 Mute Off 1 Mute On BBE Signal Processing BPxy cr x Zone...

Страница 16: ...to echo back the current state for that zone z or channel c E Ex xa am mp pl le e Zone 4 is OFF and a P4 query is received The 875D SE echoes back P40 Zone 4 power is OFF 4b A command followed by a G...

Страница 17: ...RMS 3 0V AC RMS w BBE ON Loop Output Impedance Buffered 100 ohms Serial Protocol RS 232 Connection 9600 N 8 1 single CR Power Consumption 1 200 Watts BTU HR 850 AC Fuse 10A T10AL 250V Dimensions WxHxD...

Страница 18: ...IGGER INPUTS 5 24V AC DC TRIGGER OUTPUTS 12VDC OFF LOW OFF LOW OFF LOW OFF LOW ON HIGH ON HIGH ON HIGH ON HIGH 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CH CH1 CH2 NORMAL BRIDGED NORMAL BRIDGED ALL CH CH RS 232...

Страница 19: ...AUX DIRECT LEFT RIGHT AUX DIRECT LEFT RIGHT AUX DIRECT LEFT RIGHT AUX DIRECT LEFT RIGHT AUX DIRECT LEFT RIGHT AUX DIRECT LEFT RIGHT AUX BBE CONTROL INPUTS 5 24V AC DC EXTERNAL TRIGGER INPUTS 5 24V AC...

Страница 20: ...TO VOLT AUTO VOLT AUTO VOLT AUTO VOLT TRIGGER MODE CH 1 2 CH 3 4 CH 5 6 CH 7 8 OFF ON RS 232 RS 232 RS 232 RS 232 ZONE 1 ZONE 4 ZONE 2 ZONE 3 K2 Keypad K1 Keypad K2 Keypad K2 Keypad FUSE FUSE FUSE FUS...

Страница 21: ...HIGH ON HIGH 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 CH CH1 CH2 NORMAL BRIDGED NORMAL BRIDGED ALL CH CH RS 232 1 2 3 4 5 6 7 8 ALL S N 1 2 3 4 5 6 7 8 BRIDGED 8 MIN BRIDGED 8 MIN BRIDGED 8 MIN BRIDGED 8 MIN...

Страница 22: ...onnect the AL2 Control Output to each zone where BBE processing is desired Set the BBE Control OFF ON switches in the OFF position Set the BBE LOW HIGH switches to the desired amount of BBE processing...

Страница 23: ...CONTROL BBE CONTR INPUTS 5 OFF LOW OFF LOW OFF LOW OFF LOW ON HIGH ON HIGH ON HIGH ON HIGH 1 2 3 4 5 6 7 8 CH To Zone Controller K2 Rear Panel Notes Set the BBE Control OFF ON switches in the OFF pos...

Страница 24: ...our Customer Service Department who will issue you a Return Authorization RA Number I Im mp po or rt ta an nt t Y Yo ou u m mu us st t h ha av ve e p pr ri io or r a au ut th ho or ri iz za at ti io o...

Страница 25: ...lude service or parts to repair damage caused by accident disaster misuse abuse negligence inadequate packing or shipping procedures commercial use voltage inputs in excess of the rated maximum of the...

Страница 26: ...26 SONAMP 875D SE 8 CHANNEL AMPLIFIER System Notes...

Страница 27: ......

Страница 28: ...s Inc AMX is a trademark of AMX Corporation Due to continuous product improvement all features and specifications are subject to change without notice For the latest Sonance product specification info...

Отзывы: