44
6. Release the fine-wire coaxial cable from the four hooks.
7. Disconnect the fine-wire coaxial cable from the connector (CN2005) on the AXM-62 board.
Note
•
At the time of the installation, align the tape of the fine-wire coaxial cable with the position shown in the figure.
•
At the time of the installation, make sure that the fine-wire coaxial cable is firmly on the hooks so that there is no slack in
the cables.
8. Remove the four screws, and then remove the two XLR caps, the two washers, the XLR plate, and the AXM-62 board.
9. Disconnect the flexible flat cable from the connector (CN1006) on the AXM-62 board.
10. Install the removed parts by reversing the steps of removal.
Fine-wire coaxial cable
Tape
AXM-62 board
CN2005
Hooks
XLR cabinet
Flexible flat cable
AXM-62 board
XLR plate
CN1006
XLR cap
BTP2.6 x 10
BTP2.6 x 10
Washer