background image

5

Frequency measurement (Hz)

In the frequency measurement function: 

Connect  the  red 

probe cable to the “

INPUT

” socket, and the black one to the 

COM

”  socket.  Set  the  dial  to  the  frequency  measurement 

function  (HZ%).  Use  the  “Hz%”  button  to  set  the  frequency 

measurement function (Hz). Connect the measurement probes 

to the circuit to be measured. 

Note:

 Do not exceed the input voltage, as this will damage the 

instrument.

Measurement 

limit

Resolution 

Accuracy

9,999 Hz

0,001 Hz

±(0.5%  3 digits)

99,99 Hz

0,01 Hz

999,9 Hz

0,1 Hz

9,999 kHz

1 Hz

99,99 kHz

10 Hz

999,9 kHz

0,1 kHz

9,999 MHz

1 kHz

Input voltage: 200 mV - 10V AC RMS

Over-voltage protection: 250 V DC or 250 V AC RMS

When measuring AC: 

Warning! Before performing a measurement, unplug the probe 

cables from the unit.

Set  the  dial  to  the  desired  measurement  range  (40 

A

 

400 

A

).  Use  the  “SEL”  pushbutton  to  set  the  alternating 

current (AC) function. Use the “Hz%” button to set the frequency 

measurement function (Hz).  Open the clamp, place it around the 

cable then close it. 

Measurement 

limit

 Resolution 

Accuracy

10 Hz

0,01 Hz

±(1.5%  5 digits)

1 KHz

1 Hz

>1 KHz

1 Hz

Measurement limit: 10 Hz – 1 KHz

Input  current  range:  ≥  4 A AC  RMS  (higher  input  current  is 

required at a higher frequency)

Max input current: 400 A AC RMS

When measuring AC voltage:

Connect the red probe cable to the “INPUT” socket, and the black 

one to the “COM” socket. Set the dial to the AC voltage position 

(

~V

). Use the “Hz%” button to set the frequency measurement 

function (Hz). Connect the measurement probes to the circuit to 

be measured.

Measurement 

limit

Resolution 

Accuracy

10 Hz

0,01 Hz

±(1.5%  5 digits)

1 KHz

1 Hz

10 KHz

1 Hz

>10 KHz

1 Hz

The accuracy of the 

measurement result is 

not guaranteed.

Measurement limit: 10 Hz – 10 KHz, Input voltage range: ≥ 0.6 V 

AC RMS (higher input voltage is required at a higher frequency), 

Input impedance: 10 MΩ, Maximum input voltage: 600 V AC RMS

Duty factor measurement (%)

Measuring 

range

Resolution

Accuracy

0 – 100 %

0.1 %

±3%

In the duty factor measurement function:

Connect the red probe cable to the “INPUT” socket, and the black 

one to the “COM” socket. Set the dial to the duty factor measurement 

function (HZ%). Use the “Hz%” button to set the duty factor function 

(%). Connect the measurement probes to the circuit to be measured. 

Note:

  Do  not  exceed  the  input  voltage,  as  this  will  damage  the 

instrument.  If  the  duty  factor  is  less  than  10%,  the  “UL”  symbol 

will appear on the LCD display. If it is greater than 99.9%, the “UL” 

symbol will appear on the LCD display.

Measurement limit: 1 Hz-10 MHz

Input voltage: ≥ 500 mV RMS

Over voltage protection: 250 V AC RMS

When measuring AC: 

Warning!  Before  performing  a  measurement,  unplug  the  probe 

cables from the unit. Set the dial to the desired measurement range 

(40 

A

, 400 

A

). Use the “SEL” pushbutton to set the alternating 

current (AC) function. Use the “Hz%” button to set the duty factor 

function (%). Open the clamp, place it around the cable then close it. 

Note:

 If the duty factor is less than 10%, the “UL” symbol will appear 

on the LCD display. If it is greater than 94,9%, the “UL” symbol will 

appear on the LCD display.

Measurement limit: 10 Hz – 1 KHz

Input current range: ≥ 4 A AC 

Max input current: 400 A AC RMS

When measuring AC voltage:

Connect the red probe cable to the “INPUT” socket, and the black 

one to the “COM” socket. Set the dial to the AC voltage position (

~V)

Use the “Hz%” button to set the duty factor function (%). Connect the 

measurement probes to the circuit to be measured. 

Note:

 If the duty factor is less than 10%, the “UL” symbol will appear 

on the LCD display. If it is greater than 94,9%, the “UL” symbol will 

appear on the LCD display.

Measurement limit: 10 Hz-10 KHz

Input voltage: ≥ 1 V AC RMS

Input impedance: 10 MΩ

Maximum input voltage: 600 V AC RMS

Diode and interruption testing

Diode testing: 

Connect the red probe cable to the “INPUT” socket, 

and the black one to the “COM” socket (the red probe is “+” polarity). 

Set the dial to the   position. Use the “SEL” pushbutton to set the 

diode testing ( ) function. Connect the red probe cable to diode’s 

anode, and the black one to its cathode. The display will show the 

diode’s approximate forward voltage. If the connection is reversed, 

“OL” will appear in the display. 

Interruption testing: 

Connect  the  red  probe  cable  to  the 

“INPUT”  socket,  and  the  black  one  to  the  “COM”  socket  (the 

red  probe  is  “+”  polarity).  Set  the  dial  to  the 

  position. 

Use  the  “SEL”  pushbutton  to  set  the  interruption  testing 

 

( )  function.  Connect  the  measurement  probe  to  the  circuit  to 

be tested. If the circuit is connected to a power source, switch of 

the  power  source  and  discharge  the  capacitors  before  starting 

measurement. Short-circuits (less than 40 Ω) will be indicated by 

the built-in buzzer. 

Note:

 If the measured value is more than 400 Ω, the “OL” symbol 

will appear on the display.

Содержание Home SMA 2101

Страница 1: ...o a v robce proizvo a producent SOMOGYI ELEKTRONIC H 9027 Gy r Gesztenyefa t 3 www somogyi hu SMA 2101 instruction manual eredeti haszn lati utas t s n vod na pou itie manual de utilizare uputstvo za...

Страница 2: ...ntru selectarea func iei dorite 6 buton pentru afi area valorii maxime minime a m rimii m surate 7 buton pentru afi area valorii relative a m rimii m surate decuplare automat 8 afi aj cu cristale lich...

Страница 3: ...nd discharge the high voltage capacitors before measuring resistance or interruption Be very careful when working with bare cables or bus bars If any irregular operation is detected on the clamp meter...

Страница 4: ...obe cable is not connected to the circuit being measured If the measured figure is more than 600 V the OL symbolwillappearontheLCDdisplay andthebuilt in buzzer will emit a beep Measurement limit Resol...

Страница 5: ...ceed the input voltage as this will damage the instrument If the duty factor is less than 10 the UL symbol will appear on the LCD display If it is greater than 99 9 the UL symbol will appear on the LC...

Страница 6: ...ries Observe the correct polarity Replace the cover and tighten the screw Warning Before opening the instrument make sure that the probe cables have been removed from the measuring circuit Replace and...

Страница 7: ...ne l pje t l a biztons gi hat r rt keket melyeket a haszn lati tmutat m r si intervallumonk nt meghat roz Sohanehaszn ljaazeszk ztah ts bor t s sateljesr gz t s n lk l H zza ki az ramk rb l s s sse ki...

Страница 8: ...at instabil kijelz s f leg a 400 mV os m r shat rban ha nincs a m rend ramk rre csatlakoztatva a m r zsin r Ha a m r s eredm nye t bb mint 600 V akkor az OL szimb lum jelenik meg az LC kijelz n s a be...

Страница 9: ...v nt ramk rh z Megjegyz s Ne l pje t l a bemeneti fesz lts g rt ket mert a m szer meghib sod s hoz vezethet Ha a kit lt si t nyez kevesebb mint 10 az UL szimb lum jelenik meg az LC kijelz n ha a kit l...

Страница 10: ...t T vol tsa el a csavart a h tlapb l Cser lje ki az elemeket A megfelel elempolarit sra figyeljen Csavarozza vissza a h tlapot Figyelmeztet s Miel tt az eszk zt felnyitn mindig bizonyosodjon meg arr l...

Страница 11: ...te pr stroj bez zadn ho krytu a celkov ho zafixovania Odstr te z elektrick ho obvodu a vybite kondenz tory s vysok m nap t m pred t m ako za nete s meran m odporu preru enia Bu te ve mi opatrn ke prac...

Страница 12: ...nasta nestabiln zobrazenie najm pri 400 mV hranici merania ke na meran elektrick obvod nie je pri pojen merac hrot Ke v sledok merania je viac ako 600 V tak sa na LC displeji objav symbol OL a zabudov...

Страница 13: ...ick mu obvodu Pozn mka Neprekro te hodnotu vstupn ho nap tia lebo pr stroj sa m e po kodi Ke faktor vyplnenia je menej ako 10 na LC displeji sa objav symbol UL ke faktor vyplnenia je viac ako 99 9 na...

Страница 14: ...bat rie Pred v menou bat rie vypnite pr stroj vytiahnite meracie hroty Odstr te skrutku zo zadn ho panelu Vyme te bat riu Dbajte na spr vnu polaritu bat ri Priskrutkujte zadn panel sp Upozornenie Pred...

Страница 15: ...ur rii rezisten elor rezistoarelor i sau a test rii continuit ii circuitelor ntrerupe i n prealabil tensiunea de ali mentare a circuitelor asupra c rora ve i efectua m sur torile i desc rca i condensa...

Страница 16: ...unc ie Borne de intrare COM borna de intrare negativ comun pentru toate m rimile m surate INPUT borna de intrare pozitiv comun pentru toate m rimile m surate Specifica ia tehnic referitoare la precizi...

Страница 17: ...orului de umplere Hz dup care selecta i func ia de m surare a frecven ei Hz cu ajutorul butonului Hz Conecta i cablurile de m surare la circuitul verificat Observa ie Dep irea limitei superioare a int...

Страница 18: ...elor Verificarea diodelor Conecta i cablul de m surare de culoare ro ie la borna INPUT iar cablul de m surare de culoare neagr la borna COM Polaritatea predefinit a cablului de culoare ro ie este pozi...

Страница 19: ...edat nerambursabil la locul de v nzare al acestuia sau la to i distribuitorii care au pus n circula ie produse cu caracteristici i func ionalit i similare Poate fi de asemenea predat la punctele de co...

Страница 20: ...praznite kondenzatore ukoliko merite otpor prekid diodu Budite pa ljivi kada radite sa golim provodnicima i inama Ha b rmilyen szokatlan jelens get szlel a lakatfog n a lakat fog t azonnal ki kell kap...

Страница 21: ...mernih kablova postavite na mereni strujni krug Napomena mogu e je nestabilan ispis pre svega u opsegu 400 mV na displeju dok multimetar nije priklju en na strujni krug Ako je merena vrednost ve e od...

Страница 22: ...brtni prekida postavite u polo aj HZ Tasterom Hz odaberite funkciju Pipalice mernih kablova postavite na mereni strujni krug Napomena ne prekora ite dozvoljene vrednosti ulaznog na pona to dovodi do k...

Страница 23: ...zadnje strane i skinite poklopac Zamenite bateriju Paza i na polaritet postavite bateriju i sklopite instrument Napomena Pre nego to se ure aj rastavi uvek se uverite da su merni kablovi skinuti sa s...

Страница 24: ...pite iz tokovnega omre ja in izpraznite kondenzatorje v kolikor merite upor prekinitev diodo ali kapa citeto Bodite pozorni pri delu z golimi prevodniki in inami V kolikor opazite kakr no koli nepravi...

Страница 25: ...pomba mo en je nestabilen izpis predvsem v obsegu 400 mV na zaslonu dokler multimeter ni priklopljen na tokovni krog e je merjena vrednost ve ja od 600 V se bo na zaslonu pojavil izpis OL se bo zasli...

Страница 26: ...rtljivo stikalo postavite v Hz polo aj S stikalom Hz izberite funkcijo Tipalke merilnih kablov postavite na merjeni tokovni krog Opomba Ne presegati dovoljene vrednosti vhodne napetosti to lahko pripe...

Страница 27: ...ani multimetra in snemite pokrov Zamenjajte baterijo Bodite pozorni na polarnost pri vstavljanju baterije in izklopite multimeter Opomba Preden se naprava odpira vedno se prepri ajte da so merilni kab...

Страница 28: ...Str Prof Dr Gheorghe Marinescu nr 2 Cod po tal 400337 Tel 40 264 406 488 Fax 40 264 406 489 www somogyi ro Uvoznik za SRB ELEMENTA d o o Jovana Miki a 56 24000 Subotica Srbija Tel 381 0 24 686 270 ww...

Отзывы: