Model
Panel Size(mm)
CN8-RC60W
48H×48W
48H×48W
72H×72W
72H×72W
48H×96W
48H×96W
2
2
2
2
2
2
1 Relay
1 Relay
1 Relay
1 Relay
Alarm output
Batch
CN7-RC60W
CN7-RC68W
CN4-RC60W
CN4-RC68W
No
No
Communication
No
RS485
No
RS485
No
RS485
CN 7 F R C 6 0
Alarm outputs
Control output
Power supply
48H×48W×97.5L
4
72H×72W×97.5L
7
AC/DC 100
~
240V 50/60Hz
Blank
AC/DC 24V
F
CN
48H×96W×97.5L
8
CN Series multi-function batch counter
W
Version
Version Code
W
1. Model Illustration
2. Model List
Dual line 6 digits LED display
2 Alarms
RS485 Communication Port
8
6
C
Relay
R
Blank
0
CN8-RC68W
CN W Series Multi-function Counter User Manual
2
1
Communication
Display digits
Dimension
Series
Safety Caution
To use this product safely and correctly and to prevent serious accidents,
please company with the following points.
Warning Failure to follow this point can result in serious injury or injury.
Caution Failure to follow this point can result in injury or product
damage.
The instruction of the symbol in the manual is as below.
Indicates that accidents or dangers may occur under special
circumstances.
Safety Caution can be divided into two parts: "Warning" and "Caution",
which means the following:
Warning
Caution
4.Communication parameters
Communication Protocol
Communcation type
Applicable specifications
Maximum connection quantity
Connection methord
Communication synchronization
Communication
effective distance
Communication speed
Start bit
Data bit
Parity check
Stop bit
Modbus RTU ( 16bit CRC )
RS485
EIA RS485 Standard
31pcs ( communication add setting : 1~247)
Two-wire half-duplex
Asynchronous
800m Max
2,400 / 4,800 / 9,600 / 19,200bps
(Factory settings: 9,600bps)
1 bit ( fixed )
8 bit ( fixed )
None, Even, Odd ( Factory settings: None)
2bit
Features:
⊙
Counting speed up to 20KCPS
⊙
Free setting ratio 0.00001
~
999999
⊙
Universal input. Choose “NPN” or “PNP” input through software.
⊙
Batch or total accumulation function (except CI4W), optional 1 RS485
communication interface.
⊙
Widely used in light industry, packaging, printing, textile, food and other
industries for quantity and length counting.
1. Dual safety protection devices must be installed when used in
machines that have a medium impact on people and property, such
as: nuclear power control, medical equipment, vehicles, railways,
aviation, combustion equipment, entertainment equipment, etc. Failure
to do so may result in fire, death or property damage.
2. Be sure to install the panel when using it, otherwise there is danger of
electric shock.
3. Do not perform maintenance work while the power is on, otherwise
there is danger of electric shock.
4. Do not modify this product without authorization, otherwise it may
cause electric shock or fire.
1. Do not use the product outdoors. Failure to do so may shorten the life
of the product or cause an electric shock.
2. When wiring the power input terminal and relay output terminal, please
use the AWG NO.20 (0.50mm2) cable The torque of the screw is kept
at 0.7N.m~0.9N.m. If the contact is poor, it may cause a fire.
3. Please use the product within the rated specifications. Otherwise, the
life of the product will be shortened and there is a fire hazard.
4. Please ensure the loading less than the allowable capacity of the relay
contacts. Failure to do so may result in poor insulation, contact
melting, poor contact, relay damage, fire, etc.
5. Do not use water or organic solvents when cleaning. Wipe with a dry
towel. Failure to do so may cause electric shock or fire.
6. Avoid using this product in places that are flammable and explosive,
humid, direct sunlight, heat radiation, vibration, etc. Failure to do so
may cause a fire or explosion.
7. Do not allow dust or cable residue to enter the inside of the product.
Failure to do so may cause fire or damage to the product.
CI4W
Series
CI7W
CI8W
6
6
6
3. Technical Specifications
Display digits
Text height Measured value
Setting value
High voltage type
Low Voltage type
High voltage type
Low Voltage type
INA/INB max counting speed
Minimum signal pulse width
Input type
Control
output
Contact capacity
SSR capacity
Time output delay
Vibration resistant
Malfunction &
impact resistance
External power supply
Power failure memory
Insulation resistance
Withstand voltage
Relay life
Environment
Anti-interference
(
AC power)
Vibration
shock
Malfunction
Mechanical
Electric
IP Grade
Certificate
Weight
Allowable voltage
variation range
Power
Supply
Power
Consumption
10mm
13mm
13mm
7mm
9mm
6mm
AC / DC 100-240V 50/60Hz
AC / DC 20-28V 50/60Hz
90%~110% of the power supply voltage
Below 12VA
Below 10VA
1Hz
、
30Hz
、
1KHz
、
5KHz
、
10KHz
、
20KHz optional
INHIBIT, BATCH, RESET signal for option
1ms, 20ms
0.01~499.99s
250VAC 3A Resistive load
below 30VDC , below 100mA
24VDC±10%, below 100mA
≥10 years
>
100MΩ
60 seconds below 2000VAC 50/60Hz
100m/s2(10G)X, Y, Z, 3 times in each
direction
above 10 million times
above 100,000 times
Ambient
temperature
Ambient
Humidity
-10~55 , Storage: -25~65
35~85%RH, Storage: 35~85%RH
CE
The surrounding environment must be in line with no ice, * no
condensation. The weight here is the product net weight without packing.
about 159g
about 169g
about 253g
IP65 for panel
10~55Hz (1 minute period) amplitude
0.75mm X, Y, Z 1 hour in each direction
10~55Hz (1 minute period) amplitude
0.5mm X, Y, Z 10 minutes in all directions
300m/s2(30G)X, Y, Z, 3 times in each
direction
Select voltage input mode or no voltage
input mode
- Voltage input mode: Input impedance:
5.4KΩ, "H" level voltage: 5-30VDC, "L"
level voltage: 0-2VDC
- No voltage input mode: input impedance:
1KΩ or less, short circuit residual voltage:
2VDC or less
±4KV interference square wave (amplitude
1us) generated by the analog jammer is
applied between the power input terminals
KKCNW-A01E/A0/20221031