2.3. COMMISSIONING
2.3.1. Pre-programming the control point
1) Switch on the power supply.
2) Press the
Up and Down
buttons on the control point at the
same time: The motorised product moves up and down (fast
raising and lowering), and the control point is pre-programmed
in the motor.
7KHPRWRULVDWLRQLVLQSURJUDPPLQJPRGHIRU§PLQ
2.3.2. Checking the direction of rotation
1) Press the
Up
button on the control point:
a) If the motorised product rises (a), the direction of
rotation is correct: Move onto the section entitled “Setting
the end limits”.
b) If the motorised product lowers (b), the direction of
rotation is incorrect: Move onto the next step.
2) Press the
my
button on the control point until the motorised
product moves up and down: The direction of rotation has
EHHQPRGL¿HG
3) Press the
my
button until the motorised product moves up
and down.
2.3.3. Setting the end limits
Setting the end limits in automatic mode (2.3.3.a)
1) Press the
Up and Down
buttons on the control point at the
same time: The motorised product moves up and down (fast
raising and lowering).
2) Press the
my
button until the motorised product moves up
and down.
Setting the end limits in manual mode (2.3.3.b)
The end limits can be set in any order.
1) Raise the motorised product to the desired position by
pressing the
Up
button.
2) Press the
my
and
Down
buttons at the same time until the
motorised product moves.
The upper end limit is memorised.
3) Press the
my
button when the motorised product reaches
the desired lowered position. If necessary, adjust the position
of the motorised product using the
Up
and
Down
buttons.
4) Press the
my
and
Up
buttons at the same time until the
motorised product moves.
The lower end limit is memorised. The motorised product
rises and stops in the raised position.
7R FRQ¿UP WKH HQG OLPLWV SUHVV WKH
my
button until the
motorised product moves up and down.
The end limits are programmed.
1
2
ON
1
2
3
4
5
1
2
3
a
b
Move onto
the next step
Setting the
end limits
1
2