background image

1. Identify the UP limit switch push button, on the CMO motor head.

Press the UP button of the transmitter and let the end-product reach
the required UP position, then stop it.

2. Unlock the UP limit switch push button by pressing and releasing it.
3. Repeat the above operation to set the DOWN end limit.
4. Replace the protective cap.

Installer Mode

This mode allows for readjusting of the end limits and final programming

5

IMPORTANT
If the installation is made up of several LT RTS CMO motors,
This will avoid interference with the first programming of each

motor. If several motors are connected on the

same power supply, please

6.6 - "Resetting motors back to USER MODE".

1) Provide power to the

motor. Press

on the

and

buttons of the RTS

transmitter in order to take control of the motor. Then check that the LT RTS CMO motor is in INSTALLER MODE.
In this mode the

motor runs when a directional button on the transmitter is

(momentary fashion).

2) If the end limits need to be readjusted, please refer to section - 4.3 and 4.4
3) Record the first Transmitter or Channel. On 4 channel transmitters, verify the desired channel selection before pressing the
the programming button.

only one

motor must be powered during programming.

SIMULTANEOUSLY

UP

DOWN

pressed and held

LT RTS CMO

LT RTS CMO

refer to the Warning note in Section

LT RTS CMO

LT RTS CMO

Release it when the end-product jogs briefly UP/DOWN
indicating that the transmitter has been memorized
into the motor. The motor is now in USER MODE

Press the programming button
on the RTS transmitter

User Mode

This mode is for operating the motor by the end user

Two intermediate postions (IP1 & IP2) can be programmed into the LT RTS CMO motor. IP1 is set using the UP limit as a
reference, and IP2 is set from the DOWN limit as a reference.

1) Record the INTERMEDIATE POSITION (IP1) referenced from the UP LIMIT of the end-product

6

STOP

IP1

5s

Set the end-product at
its UP limit with the
RTS transmitter

Push simultaneously on the
STOP and DOWN button of
the RTS transmitter and release
them when the end-product begins
to move.

Stop the end-product at the
intermediate position (IP1) you
wish to achieve (if necessary,
adjust this position with UP and
DOWN push buttons).

Push the STOP button of the
RTS transmitter for five seconds.

The end-product jogs
briefly UP/DOWN indicating
that the LT RTS CMO motor
has memorized the first
intermediate position (IP1)

4) Set the UP and DOWN Limits.

White Button

Yellow Button

The buttons shown may not correspond to the correct directions on the end-product.

*If the INSTALLER MODE directly follows FACTORY MODE, with no power interruption to the motor, go directly to Section 5.3

Содержание LT RTS CMO

Страница 1: ... an awning it will open or extend the awning If the UP button extends the awning the wind sensor will also extend the awning during windy conditions THIS IS DANGEROUS Damage and injury could occur Do not proceed until proper operation of the transmitter is verified 120 VAC 60 Hz The Master Channel on a 4 channel transmitter can be used as an additional individual channel for a total of 5 channels ...

Страница 2: ... POWER ON FOR FIRST TIME 1 Two positions have to be set the UP and DOWN limits This is achieved with the mechanical CMO limit switch unit Provide power to the motor Notice the motor will not respond to any transmitter until a transmitter is assigned to communicate with the motors receiver A Remove the protective cap covering the limit setting buttons on the motor head replace when finished B Depre...

Страница 3: ...USLY UP DOWN pressed and held LT RTS CMO LT RTS CMO refer to the Warning note in Section LT RTS CMO LT RTS CMO Release it when the end product jogs briefly UP DOWN indicating that the transmitter has been memorized into the motor The motor is now in USER MODE Press the programming button on the RTS transmitter User Mode This mode is for operating the motor by the end user Two intermediate postions...

Страница 4: ...indicating that the LT RTS CMO motor has memorized the second intermediate position IP2 2 Record the INTERMEDIATE POSITION IP2 referenced from the DOWN LIMIT of the end product REACH THE INTERMEDIATE POSITIONS DELETE AN INTERMEDIATE POSITION The end product jogs briefly UP DOWN indicating that the LT RTS CMO motor is in a programming state The end product jogs briefly UP DOWN indicating that the t...

Страница 5: ...Resetting the motor s memory and recording a new transmitter when the only transmitter is lost A Perform a power cut in the following sequence 1 Power off 2 sec Minimum 2 Power on 5 to 15 seconds 3 Power off 2 sec minimum 4 Power on The end product moves for 5 seconds in one direction to indicate that the double power cut has been recorded The motor is in INSTALLER MODE for 2 minutes WARNING This ...

Страница 6: ...ODE and return to USER MODE RESETTING MOTORS BACK TO USER MODE B Press more than 5 seconds on the programming button of the PREVIOUSLY recorded RTS transmitter channel The end product jogs briefly UP DOWN indicating that the LT RTS CMO motor has been completely cleared NOTE A double power cut cannot be achieved if the motor is still in FACTORY or INSTALLER Mode First program a transmitter into the...

Отзывы: