background image

IGC and IGC/3N1

Installation and Operation Instructions

IGC 

IGC/3N1 CONNECTIONS

IGC/3N1 

Connect Motor & Power Cables to the IGC & IGC/3N1 according to the wiring charts below.

Line Voltage installation must comply with local and NEC codes.

LOW VOLTAGE CONNECTIONS

DESCRIPTION

LINE VOLTAGE CONNECTIONS

The IGC system provides control of one or more motors in groups and/or individually from one or 
more locations.  This advanced yet simple to install modular control system can be activated 
manually or automatically.  The heart of the system is the IGC Motor Controller used for each 
motor.  However, greater economy can be obtained using the IGC/3N1 version for those jobs 
that call for controlling at least three motors individually or in groups.

The IGC is a very flexible control system that can be configured in a variety of ways (i.e., 
individual window control, floor control, total building control, etc.) to meet the requirements of 
your customers.

The Individual-Group Control System is compatible with other SOMFY controls (i. e., Remote 
Control, IntelliS Timer, Decorator Somfy-Matic , Comfort Control, etc.) and security, lighting, and 
HVAC systems.

The Individual IGC Controller has an added feature.  It is equipped with a dry contact input that 
can interface with a window alarm system.  One typical application is for casement windows; 
when the window is open, the motor will not operate.  This will help prevent damage to window 
coverings.

IGC

Cat. No:  6300717

IGC/3N1

Cat. No:  6300719

Note:

 An additional wire can 

be provided on the IGC for 
dry contact output capability. 
Please contact customer 
service for more information.

POWER

BLACK

WHITE

GREEN

MOTOR

WHITE

GREEN

RED

BLACK

IGC/3N1

BLACK

WHITE

RED

GREEN

BROWN

POWER

BLACK

WHITE

GREEN

MOTOR

WHITE

GREEN

RED

BLACK

IGC 

BLACK

WHITE

GREEN

RED

BROWN

C

O

M

M

O

N

C

O

M

M

O

N

C

O

M

M

O

N

N-C

I

N

P

U

T

M

A

S
U

P

M

A

S
U

P

M

A

S
D

W

N

M

A

S
D

W

N

IND

M

M

IND

IND

TM

IGC CONNECTIONS

1.

  Individual ports (IND) control only one output.  The Decorator

     IGC Switch connects to the control via 6 conductor modular
     cable.

2.

  A switch connected to the Master ports (MAS) operates all the

     motors on the control board as a group.  This port can also be
     used to connect a number of IGCs or IGC/3N1s together to form
     a group.  

3.

  For group only control from an external device, low voltage

     terminals have been provided on both the single IGC and
     IGC/3N1.  A momentary contact between the MAS UP and
     COMMON terminals will activate the Master Up command. 
     Similarly, connecting the MAS DWN and COMMON terminals will
     activate the Master Down command.  

4.

  SINGLE IGC ONLY:  The N-C (normally closed) INPUT terminal

     is for a normally closed contact connected to a casement
     window or french door.  When the door or window opens, this
     contact opens and disables the down direction.  DO 

NOT

     REMOVE FACTORY INSTALLED JUMPER IF THIS FEATURE IS
     NOT USED.

M

M

IND

Отзывы: