Electrical preequipment
Ensure that you have an Orange ICT Ø 25 mm protective sheath for underground
cabling. If a cable conduit cannot be made, use a cable grommet which will
withstand the passage of vehicles (ref. 2400484).
Power supply (230 v only)
►
Fit a 230 V electrical input as close as possible to the motor.
The motor's electronic unit must be supplied with 230 V - 50 Hz with a flexible 1.5 mm²
cable.
The electric line should be:
Exclusively reserved for the motor.
•
Fitted with protection:
•
– a 10 A fuse or breaker,
– a differential type device (30 mA).
Installed according to current electrical safety standards in the countries in which
•
it is used.
An all-pole supply cut-off device must be provided:
either by using a supply cable fitted with a plug,
•
or by using a switch ensuring a minimum separation distance between the contacts
•
of 3 mm on each pole (according to the EN 60335-1 standard).
It is recommended that you fit a lightning conductor (max. residual voltage 2 kV).
The cells (as an option in the freevia 280 pack)
►
The cells are essential for operation in automatic mode and for opening in public
areas.
Cell wiring
•
(see page 23)
Ensure that there is a sheathed connection between the two pillars for the cell wiring.
Drill holes in the two ends of the gate frame to feed through the sheaths. The cells
must be connected to the motor electronics using a 2 x 0.75 mm² cable. The feed
wires should arrive under the cells.
Cell location (see page 22).
•
orange light (optional)
►
It is recommended that you install an orange light for operation in automatic mode and
for opening in public areas.
Orange light wiring (see page 26)
•
Allow the cable to be fed through for the installation of the orange light. The orange
light must be connected to the motor electronics using a 2 x 0.75 mm² cable.
Orange light location (see page 25)
•
safety instructions
The safety instructions must be followed throughout the installation:
Remove any jewellery (bracelets, chains, etc.) during installation.
•
For drilling or welding operations, wear special goggles and sufficient protection.
•
Use appropriate tools, specified on page 6.
•
Be careful when handling the motorisation system to prevent any risk of injury.
•
Do not connect the unit to the power supply or to the backup battery (optional) before the
•
installation process is complete.
Never use high pressure cleaning equipment.
•