5
EN
End limit setting and self-learning
Fig. 16
For swinging doors, change the P9 setting before starting self-learning.
[1].
Press the “
SET
” button until the light comes on (2 s).
The display shows “
S2
”
[2].
Control the motor using the “
+
” or “
-
” buttons so that the transmission system runner moves to link up with the trolley and closes the door.
• Pressing and holding the “
-
” button
closes
the door.
Release the “-” button before the motor has time to force against the door.
• Pressing and holding the “
+
” button
opens
the door.
[3].
Adjust the closed position using the “
+
” or “
-
” buttons.
Release the “-” button before the motor has time to force against the door.
[4].
Press “
OK
” to validate the closed end limit position and start the self-learning cycle.
The door runs through a complete Open Close cycle.
• If learning was correct, the display will show “
C1
”.
• If the learning cycle was not completed correctly, the display will show “
S1
”.
During the learning cycle:
• If the door is moving, pressing any button will stop the movement and interrupt the learning mode.
• If the door is stopped, pressing “
SET
” once will exit the learning mode.
You can call up the learning mode at any time, even when the learning cycle has already been executed and the display shows “
C1
”.
Memorising the remote controls for operation in «Total opening» mode
Fig. 17
Up to 32 control channels can be stored.
Running this procedure for a previously stored channel will clear it.
At this stage in the installation process, the Dexxo Pro motor drive unit is ready to run.
PROGRAMMING
. Press for 2 s: memorise remote controls
. Press for 7 s: delete remote controls
. Modifying a setting value
. Using the forced mode
. Selecting a setting
. Start the learning cycle
. Confirm setting selection
. Confirm setting value
. Press for 0.5 s: call up and exit the setup menu
. Press for 2 s: start learning
. Press for 7 s: clear learning and settings
. Stop learning
Programming button description
OPERATING TEST
Using the remote controls
Fig. 18
Obstacle detection function
Fig. 19 and 20
The detection of an obstacle during door opening will stop the door
(Fig. 19)
.
The detection of an obstacle during door closure will reopen the door
(Fig. 20)
.
Make sure that obstacle detection works when the door encounters an obstacle 50 mm from the ground.
Built in lighting operation
The light will come on every time the motor drive unit is operated. It will go out automatically after one minute once the door stops. This time delay
is adjustable (refer to the Setup chapter). Repetitive use which causes the light to stay on continually may result in an automatic cut-off condition
triggered by the thermal cut out protection mechanism.